background image

  

 

DV26-en-US_V1.3  12/21 

 

Power ON for use without Audible Alarm 

1.

 

Press and hold the power button (5) for at least 3 seconds. The red LED will flash quickly once and then the steady green 
LED light will appear near the tip of the sensor (6). 

2.

 

The unit is now ready for operation without audible feedback.  

Taking Measurements 

1.

 

Please test on a known live circuit to verify proper functionality first.

 

2.

 

Touch the probe tip (7) to the hot conductor or insert into the hot side of the electrical outlet.

 

3.

 

If AC voltage is present, the detector cone will illuminate (6) and the detector will beep. The stronger the voltage, the faster 
the audible and visual alarming.

 

Switching the unit OFF 

Press and hold the power button (5) for 2 seconds. The unit will emit a long audible tone and the LEDs will switch off. The unit 
also switches OFF automatically after 5 minutes of non-use.  

Important note on the meter’s sensitivity

 

This detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This 
is normal operation. 

Flashlight Function 

The ON/OFF button (2) controls the flashlight (1). 
 

BATTERY INSTALLATION 

1.

 

Remove the end cap by gently lifting the pocket clip (4) to release the catch. 

2.

 

Insert two AAA batteries (observe polarity). 

3.

 

Replace the end cap 
 

NOTE

: If the meter does not work properly, check the batteries to make sure that they are still good and that they are 

properly inserted.  

The end user is legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the 

household garbage is prohibited! 

Deposit used batteries / accumulators at the appropriate collection points or wherever batteries / accumulators 
are sold! 

Disposal: 

Follow the valid legal stipulations with respect to the disposal of the device at the end of its lifecycle. 

 Two-year Warranty  

Teledyne FLIR LLC warrants this Extech brand

 

instrument

 to be free of defects in parts and workmanship for 

two years

 from 

date of shipment (a six-month limited warranty applies to sensors and cables). To view the full warranty text please visit: 

http://www.extech.com/support/warranties

. 

 

Calibration and Repair Services 

Teledyne FLIR LLC offers calibration and repair services

 for the Extech brand products we sell. We offer NIST traceable 

calibration for most of our products. Contact us for information on calibration and repair availability, refer to the contact 
information below. Annual calibrations should be performed to verify meter performance and accuracy. Product specifications 
are subject to change without notice. Please visit our website for the most up-to-date product information

www.extech.com

. 

 

Contact Customer Support 

Customer Support Telephone List

https://support.flir.com/contact

 

Calibration, Repair, and Returns

[email protected]

 

Technical Support

https://support.flir.com

 

 

Copyright 

©

 2021 Teledyne FLIR LLC 

All rights reserved including the right of reproduction in whole or in part in any form 

www.extech.com

 

Отзывы: