Programmable DC Power Supply 

200 Watt (40 Volts / 5 Amps) 

 

 
Model 382280

 

 

 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

Introduction 

Congratulations on your purchase of the Extech 382280 Programmable DC Power 
Supply. This 200 watt power supply offers an adjustable 5ADC / 40VDC output plus fixed 
outputs (5VDC and 3.3VDC). Programming features include custom over-voltage/current 
protection with delay timer, 199-test storage, and automated testing. Careful use of this 
power supply will provide years of reliable service. 

 

 

382280 

Содержание 382280

Страница 1: ...382280 Programmable DC Power Supply This 200 watt power supply offers an adjustable 5ADC 40VDC output plus fixed outputs 5VDC and 3 3VDC Programming features include custom over voltage current protec...

Страница 2: ...ble Currrent 0 2 9mA Fixed 5V 0 25V Fixed 3 3V 0 16V Response Time 150 ms Temperature Coefficient 100ppm o C Load Regulation 1mV Amp Line Regulation No effect if line voltage is within 90V and 130V fo...

Страница 3: ...mming value 12 RIGHT Arrow Press to move the cursor to a new location in a row 13 POWER ON OFF Press to turn the supply on or off 14 Rubber feet 15 Dot matrix display 16 GND Ground terminal connected...

Страница 4: ...e as desired 3 To change the values of voltage or current use the V A button to move the underline cursor to first digit of the voltage or current display enter the value directly from the numeric key...

Страница 5: ...the middle of the lower line of the display Over Current Protection OCP Over Current Protection OCP allows the user to set a maximum permissible current If the current limit is exceeded the unit autom...

Страница 6: ...he first and last steps Each test setup memory location represents one step The duration the step is programmable from 0 01 to 60 seconds and is programmed when the steps are stored Note Initial setup...

Страница 7: ...ived the unit will clear the entire command buffer Summary of Commands STBY cr place the unit in standby mode OPER cr place the unit in operating mode V xx xxx cr set the voltage output A x xxx cr set...

Страница 8: ...racter V or A is the programmed value while the second set of data is the read back A D value The third set of data is the status CV CC of the unit If the third set of data shows 0V the unit is placed...

Страница 9: ...transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modif...

Отзывы: