Series Connection (Channels 1 and 2, adjustable outputs) 

1.  Set the tracking switch (20) to the spring OUT position. Press in tracking switch (23). 
2.  In Series mode, the slave output will strictly track the master output voltage when the user 

turns the master voltage adjust knob (11). The output voltage in Series mode can be set up to 

double the maximum voltage available in Independent mode (voltage between terminals 19 & 

26). 

3.  Ensure that both channels’ negative terminals are NOT connected to case ground. If they are, 

a short circuit will occur. 

4.  When the two outputs are configured in Series, the voltage is controlled by the master output 

knob (11), but the current adjustment for the two outputs is still independent. Therefore, ensure 

that the CC adjust knobs (4 and 13) are rotated fully clockwise to maximum for the Series 

circuit to work correctly. 

5.  The user must physically short the negative terminal of the Master output (CH1-) with the 

positive terminal of the Slaved output (CH2+). 

 

Parallel Connection (Channels 1 and 2 adjustable outputs) 

1.  Press in both tracking switch (20) and tracking switch (23). 
2.  In Parallel mode, the two outputs will always be the same for any setting of the master voltage 

knob (11). The slave CC indicator (5) will switch on. 

3.  In Parallel mode the CC adjustment (4) for the slave is not active. The user must adjust the CC 

for the master (CH1) output (13). The current available in parallel mode is up to twice the 

amount available in other modes. 

4.  The user must short the two positive terminals. (CH1+ to CH2+) 
5.  The user must also short the two negative terminals. (CH1- to CH2-) 
6.  Use CH1 voltage control knob (11) to control the voltage level. 
7.  Use CH1 CC knob (13) to control current. 

 

Input Voltage - Switch and Fuse 

The input voltage switch is set to 115V from the factory and comes with the F8AL/250V fuse 

installed.  If operating the Power supply with 230V input the fuse must be changed to the 

F4AL/250V fuse (supplied). 

 

1.  Set the Voltage input switch to the desired setting.  
2.  Insert the correct fuse into the fuse holder based on the input voltage. 

 

115V   F8AL/250V   5x20mm 

 

230V   F4AL/250V   5x20mm 

 

Remove the fuse from the SPARE fuse holder in the AC input receptacle, as needed. 

 
 