382100-EU-EN v2.2 07/13
6
Weight
Meter: 1049g (2.3 lbs.) (with batteries); Clamp: 522g (1.2 lbs)
Dimensions
Meter: 225 X 125 X 64 mm (8.86 X 4.92 X 2.52“)
Clamp: 210 X 64 X 33mm (8.3 X 2.5 X 1.3”)
Clamp Jaw: 86 mm (3.4”)
Accessories Included
Instruction manual
Test Leads: 1 Set (4 pieces)
Alligator clips: 1 Set (4 pieces)
Clamp Probe (3)
AC to DC 9V adapter
SD card (2G)
Carrying case
2.1 Electrical Specifications
ACV
Range Resolution
Accuracy
10.0V to 600.0V
Phase to neutral line
0.1V ±
(0.5%+0.5V)
10.0V to 600.0V
Phase to phase
ACA
Range Resolution
Accuracy
20A 0.001A/0.01A
±
(0.5%+0.1A)
200A 0.01A/0.1A
±
(0.5%+0.5A)
1200A 0.1A/1A
±(0.5%+5A)
Power Factor
Range Resolution
Accuracy
0.00 to 1.00
0.01
± 0.04
PFH (Power Factor Hours): Long Term Power Factor
For three phase/four wire and three phase/three wire configurations:
PF = (PF1 + PF2 + PF3) / 3
For single phase three wire configurations:
PF = (PF1 + PF2) / 2
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524