background image

3                                                    

160310/330   7/98 Ver. 1.02 

3.1.1 Keypad Function Explanation 

KEY FUNCTION 

ZERO 

Sets the scale in the correct zero position for accurate operation. 

TARE 

Establishes either the weight currently on the platform or the current keyed-
in value as the tare weight. 

Numeric Keys (0-9) 

Allows entry of numeric data. 

Allows entry of decimal point position when entering numeric data. 

WT. SET 

Establishes the current keyed-in value as the piece count of items currently 
on the platform. 

SAMPL 

Establishes the current keyed-in value as the piece count of items currently 
on platform 

CE 

Clears the current keyed-in value or the unit weight. 

CHECK 

Toggles between present indication and the check limit setting. 
Also allows programming of check limit. 

M+ 

Ads the current number displayed in the PIECES window to the accumulator. 
() 

MR 

Toggles the scale between current indication and the contents of the 
accumulator. (Memory Recall) 

CM 

Clears the contents of the accumulator.  (Memory Clear) 

 

3.2 Display Modes 

In the COUNTING mode, the 16 digit display simultaneously indicates WEIGHT, PIECE 

WEIGHT, and QUANTITY. In the TOTALS mode, the display simultaneously indicates the 

number of counting operations totaled and the accumulated total quantity. 

 ZERO 

Indicator:

 Indicates that the scale is within 1/4 of a graduation

 

 

 WEIGHT 

Display

: Indicates the gross or net (when Tare is activated) presently on the 

platform. 

 

 PIECE 

WEIGHT 

Display

: Indicates the averaged or user-programmed sample piece 

weight. 

 

 QUANTITY 

Display

: Indicates the accumulated total number of pieces weighed 

3.3 Indicators and Warnings

 

The scale's keypad incorporates 'tactile feedback' meaning that when a key is pressed an 

audible tone is heard to confirm that a keypad command has been accepted. In addition, the 

following status indicators advise the operator:  

 ZERO 

Indicator:

 Indicates that the scale is within 1/4 of a graduation of zero. 

 TARE 

Indicator:

 Warns that a Tare value has been stored in memory. 

 ‘Light 

Sample’:

 Indicates that the unit piece weight is too light for accurate counting. This 

warning permits counting operations to continue however.

 

 ‘More 

Samples 

Needed’:

 The total number of the samples on the platform is below the 

limit necessary for accurate counting. 

3.4 Tare Operation 

In order to subtract the weight of the container or vessel from the scale’s reading, it is 

necessary to enter that weight as the tare weight.  This value can be entered into the 160310 

Отзывы: