Using the System

System Maintenance

System Startup

When the diverter valve is in the vertical position 

water will come through your sink’s faucet into your 

sink. You can still use faucet as you normally would.

When the diverter valve is in the horizontal position 

water will be sent to the RO System and pure clean 

drinking water will come through your RO faucet.

Turn the Diverter Valve to the horizontal position to direct flow 

to your RO System. 

Turn on the cold water from your feed faucet.

When using the RO Faucet the waste water (carrying rejected contaminants away from the RO membrane) 

will pour from the smaller port into your sink. Never drink this waste water, although it can be use for 

some household uses like water plants.

This RO System contains Filters that must be replaced at regular intervals to maintain proper performance. 

Use only authentic Express Water filters.

How to Change the SED (Sediment), GAC 

(Granular Activated Carbon), and PAC (Post 

Activated Carbon) Filters

(Recommended about every 6 months)

1.

 You will need Express Water inline Sediment, 

Granular Activated Carbon, and Post Activated Carbon 

Filters. We also recommend a bucket or bin large 

enough for the system to sit in. The system will release 

water when it is disassembled.

2.

 Make sure that water flow to the system is off

3.

 Place the RO System in the bucket or a sink and disconnect the the elbows from each side of the SED, GAC, 

and PAC filters. For detailed directions of disconnecting these refer to the Quick Connect Guide (Page 12)

 

One side of the SED has an inflow tube instead of an elbow

 

One side of the PAC has the faucet adapter which must be unscrewed

4.

 Note the correct orientation and flow direction of these filters then remove the filters and discard them.

5.

 Set the new filters in place in the same orientation

6.

 Reconnect the stem elbows, tube, and faucet adapter to the new SED, GAC, and PAC filters 

7.

 If these are the only filter you are changing begin the “System Startup” instructions on Page 14.

Once you are sure there are no leaks and water has begun to 

come out of the RO Faucet, let the system run for two hours. 

This will flush out any loose carbon fines and prime your filters. 

Inspect your system occasionally during this time to make sure 

there are no leaks.

 

Your water may be cloudy for the first week of operation. 

This is just air bubbles escaping from the new system. You can 

shift the sides of your system up and down while running your 

water to help this air escape.

Now your system is ready for use and the water from the RO 

Faucet is ready to drink.

Filter Change Instructions

Содержание EZRO5

Страница 1: ...Customer Support 1 800 992 8876 RO Countertop System Installation Manual ...

Страница 2: ...t solution for safe clean water in your home We know life isn t always so simple though If you have questions during your setup we can help Just give us a call during normal business hours at 1 800 992 8876 Monday Friday 10am 5pm PST Connection Points A to B Connect the WHITE Tubing from the Diverter Valve Out Point A to the Sediment Filter s IN Point B C to D Connect the BLACK Tubing from the Div...

Страница 3: ...e and local laws and codes regarding plumbing even if they differ from what is stated in this manual If your state law requires use a professional licensed installer or plumber who meets the requirements of this system All o rings fittings filter canisters and teflon tape wears out after a certain period of time The lifetime of your components are subject to change with the quality of the water su...

Страница 4: ...g Quick Connect Guide Installation Diverter Valve RO Faucet Using the System System Startup System Maintenance Filter Change Instruction Troubleshooting FAQ Warranty Page 8 Page 10 Page 11 Page 12 Page 13 Page 13 Page 14 Page 14 Page 15 Page 15 Page 16 Page 17 Page 18 ...

Страница 5: ...running right away just remove your aerator and screw the diverter valve on We support 13 16 male threaded faucets 13 16 female threaded faucets and 15 16 female threaded faucets If you have another type of faucet you will need to visit a home or plumbing supply store to adapt from your faucet type to 13 16 male as the diverter valve is 13 16 female Get Ready for Pure Water The flow through your f...

Страница 6: ...hite Tubing 3ft Diverter Valve Female 13 16 Fits 13 16 male thread Faucet Adapters 13 16 Male to 13 16 Male 15 16 Male to 13 16 Male Black Tubing 3ft Locking Clips Push Fit RO Faucet System Diagram 1 Diverter Valve 2 System Feed Tube 3 System Drain Tube 4 Sediment Filter 5 Stem Elbow 1 4 6 Granular Activated Carbon Filter 7 Male Elbow 1 8 8 RO Membrane Housing 9 Drain Flow Restrictor 10 Union Conn...

Страница 7: ... damage your tubing as you unpack it NOTE Make sure to remove any plugs before attempting to insert tubing Plug Collet Locking Clip Fitting Release Tubing Plugs If there is a Locking Clip on the Collet it must be removed before the Tubing can be released Push and hold the Collet in to release the lock while pulling out on the Tube Plugs NOTE Collet must be held down while pulling up on the tube to...

Страница 8: ...to sit in The system will release water when it is disassembled 2 Make sure that water flow to the system is off 3 Place the RO System in the bucket or a sink and disconnect the the elbows from each side of the SED GAC and PAC filters For detailed directions of disconnecting these refer to the Quick Connect Guide Page 12 One side of the SED has an inflow tube instead of an elbow One side of the PA...

Страница 9: ... the system is 45 and the maximum PSI is 80 If your PSI is too high you can purchase a Pressure Regulator to reduce your pressure to acceptable levels Let us walk you through these options call us at 1 800 992 8876 Monday Friday 10am 5pm PST or visit expresswater com Does this unit soften water Your RO System will soften water However hard water does reduce the lifespan of your filters What is the...

Страница 10: ... year from the date of original purchase Not Covered This warranty does not cover labor for removal or installation accumulation of dirt or grime you are responsible for your own cleaning systems with the serial number removed or altered damage from improper storage high or low temperature sun damage etc damage from a system not installed as instructions directed anyone other than original purchas...

Страница 11: ......

Отзывы: