14
Restarting The System
1.
Fully open the Feed Water Adapter Valve, Cold Water Supply, and the Tank Valve [if you are using a
tank].
[If not using a tank simply let pure water flow for 15 minutes]
[SKIP 2-5 IF NOT USING A TANK]
2.
Open the Pure Water Outflow and fully empty the tank before turning your outflow off.
3.
Let the system refill with water (the time will vary depending on the size of your tank and your incoming
water quality). You can open your Pure Water Outflow briefly to release any air trapped inside the system
while it’s filling. (Be sure to check for new leaks during the first 24 hours after restarting)
4.
After the Water Storage Tank has filled CLOSE the Feed Water Adapter Valve and drain the entire system
by opening your Pure Water Outflow until water flow stops. Then stop your outflow.
5.
Repeat steps 3 and 4 again to fully flush the system.
NOTE!
If the RO System is connected to an appliance do not drain the system through these devices. The
excess carbon fines from the new carbon filter can clog or damage your appliance.
(Recommended Once a Year)
1.
Before you begin you will need a new Sediment Filter, 2 Carbon Block Filters, RO Membrane, Post
Activated Carbon Filter, Filter Housing Wrench, and a container to mix water and bleach. We also
suggest using a bin large enough for the system to sit in (the system will release a lot of water when it is
disassembled).
2.
Close any incoming water (Feed Water Adapter Valve page 7).
3.
Open pure water outflow and drain the system completely (wait until water flow stops completely), then
close the outflow.
4.
Use the Filter Housing Wrench to open the Filter Housings, then remove and dispose of ONLY the
following filter cartridges:
Sediment Filter
2 Carbon Block Filters
RO Membrane
NOTE!
Leave the Inline Carbon Filter in place! You will replace it after sanitizing the system.
5.
Mix 1 gallon of water with 2 tbsp of household bleach. Do not add bleach directly to the filter housing.
6.
Fill up the Prefilter Housings (Sediment and the 2 Carbon Block Housings) with your mixed solution and
close the housings using your Filter Housing Wrench.
7.
Open the incoming water to the system (Feed Water Adapter Valve page 10) and let it run for 10
minutes.
8.
Open your Pure Water Outflow and let it drain for 10 minutes.
9.
Close the Pure Water Outflow and wait for 10 minutes then open the Outflow again and wait for it to
drain completely.
(If you smell bleach from your pure water outflow repeat steps 7-9)
10.
You are now ready to replace all filters and restart your system. Please refer to page 13 for detailed
instructions, ignore any additional sanitation steps therein.
How to Sanitize your RO System
Содержание Commercial Reverse Osmosis System
Страница 1: ...Customer Support 1 800 992 8876 Commercial Reverse Osmosis System Installation Manual ...
Страница 4: ......
Страница 6: ......
Страница 24: ...18 Notes Date ...
Страница 25: ...19 Notes Date ...
Страница 26: ...20 ...
Страница 27: ...21 ...
Страница 28: ...www expresswater com 1 800 992 8876 ...