OFFICE LINE
30
On Leva Multiboiler machines the temperature of each group boiler can be programmed and adjusted
individually via the digital temperature adjusting system.
The temperature control is performed by a PID thermostat, which provides accurate and stable
temperature management for the group.
During normal mode, the temperature display shows
the current temperature of the group boiler. When
the boiler’s heating element is working and water is
heating up, a small blue dot will illuminate to indicate this
function.
Note:
Adjust the group boiler’s temperature up with the
button and down with
button.
To turn the thermostat and its group boiler off, press and hold
the
button for 2 seconds. The thermostat selected will be
disconnected, “OFF” will be displayed, and the group will start to
cool down.
To connect the thermostat:
If the thermostat is “OFF”, press either the
or
button. The thermostat will be turned back on and the group’s
current temperature will be displayed as the group boiler
starts to heat up.
To adjust the group operating temperature setting follow the
steps below:
• Press and hold the
button until the temperature display
shows “PrG”.
• Within 2 seconds, press the
button, the display will show
the current group temperature setting.
• Within 2 seconds, begin to adjust the temperature setting up
with the
button, or down with the
button.
• When the desired temperature is displayed, wait 3 seconds.
The thermostat will automatically return to normal mode with
the new temperature setting.
LEVA MULTIBOILER TEMPERATURE CONTROL
Normal mode
Turning the thermostat and group boiler off/on
Adjusting the group boiler temperature
i
i
90.
off
P
r
G
92
Note:
The instructions on this page apply to Leva Multiboiler machines only.
Buttons
Heating
Element
Lamp
Group Boiler Temp.