![Explo GX3 Power Flame Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/explo/gx3-power-flame/gx3-power-flame_manual_2451953006.webp)
6
24
VENT (Careful, the gas will not be ignited)
25
STOP recharge routine
26
START recharge routine
•
Control via DMX
Channel
Function
1 (0-255)
Ignition
≤ 253 = no ignition
254 and 255 = Ignition
2 (128)
Opening time
0 = 0,5 sec
255 = 2,5 sec
3 (0-128-255)
Status
0-84 = Pilot flame
85-170 = Power Flame with recharge
171-255 = Power Flame without recharging
4 (0-128)
Mode
<50 = Test
50-200 = Armed
> 200 = Test
•
Disassembling the system
Vent the tank using Channel 24 after the last ignition, or ignite channel 17. Repeat at least 3 times.
After disconnecting the hose, E should be pressed to disarm the device, and vent it.
•
Technical Data
Power Supply:
230VAC / max. 100W
Size:
410x410x550mm
Weight:
ca. 12kg
Gas connector:
Euro-Norm, 30mm Wrench width
•
Safety Notes
The device may only be used when it is in usable and well kept condition. Defective devices must be
checked and repaired by the manufacturer, or qualified personnel. Uner no circumstances may
defective devices be used. The devices should be placed on solid, even ground, in a horizontal
position.
The safety distances mentioned in the manual are to be adhered.
All persons taking part in the gasprojector show (eg. Actors, set up helpers,..) are to be informed
about the safety distances, hazards, and the general functions of the gasprojector.
The person in charge of controling the projector, should always have clear line of sight to the devices.
Either directly, or by camera. This person is in charge of taking heed of the safety distances during
the show, and interrupt the show immediately, in case of danger.
Before usage, the system should be checked for leak tightness, to prevent an unwanted escape of
gas. Should gas leak from the system, all safety valves must be closed, and the hazardous area be
evacuated.