24 

VENT (Careful, the gas will not be ignited) 

25 

STOP recharge routine 

26 

START recharge routine 

 

 

Control via DMX 

Channel

 

Function

 

1  (0-255) 

Ignition 

 ≤ 253 = no ignition 

 

254 and 255 = Ignition 

2  (128) 

Opening time 

 0 = 0,5 sec 

 

255 = 2,5 sec 

3  (0-128-255) 

Status 

0-84 = Pilot flame 

 

85-170 = Power Flame with recharge 

 

171-255 = Power Flame without recharging 

4  (0-128) 

Mode 

<50 = Test 

 

50-200 = Armed 

 

> 200 = Test 

 

 

Disassembling the system 

Vent the tank using Channel 24 after the last ignition, or ignite channel 17. Repeat at least 3 times. 

After disconnecting the hose, E should be pressed to disarm the device, and vent it.  

 

Technical Data 

Power Supply: 

 

230VAC / max. 100W 

Size: 

 

 

410x410x550mm 

Weight:   

 

ca. 12kg  

Gas connector:    

Euro-Norm, 30mm Wrench width 

 

Safety Notes 

The device may only be used when it is in usable and well kept condition. Defective devices must be 

checked  and  repaired  by  the  manufacturer,  or  qualified  personnel.  Uner  no  circumstances  may 

defective  devices  be  used.  The  devices  should  be  placed  on  solid,  even  ground,  in  a  horizontal 

position. 

The safety distances mentioned in the manual are to be adhered. 

All  persons  taking  part  in  the  gasprojector  show  (eg.  Actors,  set  up  helpers,..)  are  to  be  informed 

about the safety distances, hazards, and the general functions of the gasprojector. 

The person in charge of controling the projector, should always have clear line of sight to the devices. 

Either directly, or by camera. This person is in charge of taking heed of the safety distances during 

the show, and interrupt the show immediately, in case of danger. 

Before  usage,  the  system  should  be  checked  for  leak  tightness,  to  prevent  an  unwanted  escape  of 

gas.  Should  gas  leak  from  the  system,  all  safety  valves  must  be  closed,  and  the  hazardous  area  be 

evacuated. 

Содержание GX3 Power Flame

Страница 1: ...rer Völkermarkterstrasse 240 9020 Klagenfurt am Wörthersee Austria Tel 43 0 463 32 2 45 Fax 43 0 463 32 2 45 75 Mobil 43 0 664 51 007 51 www explo at office explo at Explo Zündtechnik GX3 Power Flame Manual v1 3 as of November 2016 ...

Страница 2: ...s a potential hazard When using gasprojectors the local laws for gatherings as well as firehazards and gas usages are to be adhered If you have any questions that these instructions cannot answer please do not hesitate to contact us either by phone or mail We hope you have a lot of fun and success with your explo system The Team of explo General Overview Description of components Overview The GX3 ...

Страница 3: ...3 Overview of components ...

Страница 4: ...lop To quench only use CO extinguishers Positioning the system The flame projectors may only be used outdoors For the safety distances the following is true Generally the flame projector must have enough distance to all living beings and objects so that they may not be harmed or damaged by the usage of the flame projector The manufacturer recommends a distance of 5meters around and 20meters in hei...

Страница 5: ...e itself is still ready for ignition 1 The Power Flame recharges after reaching the maximum pressure too often Small leak 2 The prescribed loading time as a whole has been overstepped Medium leak 3 Pressure falls strongly during a charge Medium leak 4 The pressure stays beneath the safe value even though it s charging No gas connected Great leak Overpressure valve is open Control via radio The con...

Страница 6: ...is in usable and well kept condition Defective devices must be checked and repaired by the manufacturer or qualified personnel Uner no circumstances may defective devices be used The devices should be placed on solid even ground in a horizontal position The safety distances mentioned in the manual are to be adhered All persons taking part in the gasprojector show eg Actors set up helpers are to be...

Страница 7: ...7 Attachment In the attachments you can find the current Conformity declaration ...

Страница 8: ...ialnumber Function The Flame projector Power Flame uses an integrated pressure tank to eject propane buthane gas taken from 1 2 10Kg bottles with 7bars of pressure Using an integrated ignition electrode a separate pilot flame is ignited As soon as the pilot flame burns the main valve is opened to ignite the actual flame effect Content of the pressure tank Hereby we declare that the device in its c...

Отзывы: