![Explo GX3 Power Flame Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/explo/gx3-power-flame/gx3-power-flame_manual_2451953005.webp)
5
it features a left threading. Up to two gas bottles can be used to supply the GX3 Power Flame.
•
Charging routine
Directly after switching the device on, in TEST mode, the gas bottle will be pressurized using the inert
gas for about 30seconds.
After putting the device into ARMED mode, the gas bottle will be pressurized for 10 seconds using
the inert gas. Now gas will be filled into the tank, until 8bars are reached. Should these not be
reached, the bottle will again be pressurized and reloaded, until they are reached.
The charging routine may only be altered in the menu at the submenu Reload-Settings, by qualified
personnel.
•
Warnings
A Warning shows that the Power Flame should be checked during use, since an error has occured. It
will be showsn in the display with "Warn:" and a number. A Warning will interrupt the charging
routine. The device itself is still ready for ignition.
1
The Power Flame recharges after reaching the maximum pressure too often.
•
Small leak
2
The prescribed loading time as a whole has been overstepped.
•
Medium leak
3
Pressure falls strongly during a charge
•
Medium leak
4
The pressure stays beneath the safe value even though it's charging
•
No gas connected
•
Great leak
•
Overpressure valve is open
•
Control via radio
The control of the GX3 Power Flame can only be made via radio or DMX. The Box number can be
altered in the menu.
Channel
Function
1
Pilotflame (1 Sek)
2
Main flame (0,5 Sek)
3
Main flame (1 Sek)
4
Main flame (1,5 Sek)
5
Main flame (2 Sek)
6
Main flame (2,5 Sek)
7
Main flame (3 Sek)
11
Pilotflame (1 Sek) without recharging
12
Main flame (0,5 Sek) without recharging
13
Main flame (1 Sek) without recharging
14
Main flame (1,5 Sek) without recharging
15
Main flame (2 Sek) without recharging
16
Main flame (2,5 Sek) without recharging
17
Main flame (3 Sek) without recharging
21
Pressurize gas bottle with inert gas
22
Fill tank with gas
23
Pressurize tank with inert gas