background image

 

SERIAL TO ETHERNET   

 

CONVERTER

 

 

 

EX-9132-2  

 

User Manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Содержание EX-9132-2

Страница 1: ...1 SERIAL TO ETHERNET CONVERTER EX 9132 2 User Manual ...

Страница 2: ...oduct Specifications 9 Converter Description Installation 11 Product Panel Views 11 Left Side 12 Right Side 13 LED Indicators 14 Terminator Reset Button 15 Wiring Architecture 16 RS 232 16 RS 422 RS 485 17 Converter Configuration 18 Initial IP Configuration 18 Device Management Utility of EXPERTDAQETM 19 ...

Страница 3: ...ated 31 FactoryDefault Setting 32 Self Testing 33 Hyper Terminal for TCP IP WinSock 34 Hyper Terminal for COM Port 37 Data Transmission 37 Appendix A FAQ 38 Appendix B Pin Outs and Cable Wiring 39 DC Power Outlet 39 RJ 45 Pin Assignment 39 RS 232 Pi Assignment 39 RS 422 Pin Assignment 40 RS 485 Pin Assignment 40 ...

Страница 4: ...nverter ensures the compatibility of network software that uses a standard network API Winsock or BSD Sockets by providing TCP Server Mode TCP Client Mode and UDP Mode ARM 7 Series Virtual COM driver software that works with COM port can be set up to work over a TCP IP network in no time This excellent feature preserves your software investment and lets you enjoy the benefits of networking your se...

Страница 5: ...rter ensures the compatibility of network software that uses a standard network API Winsock or BSD Sockets by providing TCP Server Mode TCP Client Mode and UDP Mode ARM 7 Series Virtual COM driver software that works with COM port can be set up to work over a TCP IP network in no time This excellent feature preserves your software investment and lets you enjoy the benefits of networking your seria...

Страница 6: ...product is shipped with the following items 1 unit of EX 9132 2 TCP IP converter 1 unit of Power Adaptor 9VDC 500mA Documentation Software CD NOTE Notify your sales representative if any of the above items is missing or damaged ...

Страница 7: ...o manage complicated network TCP IP protocols ARM 7 Series is a low cost while providing high performance network solution by converting data stream between network TCP IP and popular serial port signals In stead of processing TCP IP packets directly devices need only deal with those interface signals which greatly simplifies the complexity of TCP IP network in linkage ...

Страница 8: ...d Support 10 100 Mbps Ethernet auto detected Server Client Dual Modes ARM 7 Series can be configured as network server or network client In the client mode it can be installed in network which is protected by NAT router or firewall without the need of a real IP address Web based Setup Parameters setup is based on HTTP protocol by using standard browsers IE and Netscape No special software would be...

Страница 9: ...P HTTP DHCP Mode TCP Server TCP Client UDP Setup HTTP Browser Setup IE Netscape RS 232 Console Security Setup Password Protection Built in 1 5KV Magnetic Isolation Serial Port Port RS 232 1 Port RS 422 RS 485 1 Port Speed 300 bps 230 4 K bps Parity None Odd Even Mark Space Data Bit 5 6 7 8 Stop Bit 1 2 RS 232 Pins Rx Tx GND RTS CTS DTR DSR DCD RS 422 Rx Rx Tx Tx Surge Protect RS 485 Data Data Surg...

Страница 10: ...485 Terminal Resistor 15KV ESD for all signals Watch Dog Function Power DC 9 12 V 500mA Led Lamp SYS PWR LAN Rx Tx Environment Operating Temperature 0 50 Storage Temperature 10 70 Dimensions 110 90 30 mm W D H Weight 146 gm ...

Страница 11: ...11 Converter Description Product Panel View LAN DC In Power Outlet LED Indicators Serial Port RS 485 RS 422 Serial Port RS 232 Reset Button RS 422 485 Terminator ...

Страница 12: ...t side of EX 9132 2 TCP IP converter and put the adapter into the socket If the power is properly supplied the SYS red color LED will be blink each time in one second LAN Port The connector for network is the usual RJ45 Simply connect it to your network switch or Hub When the connection is made the LAN LED indicator will light When data traffic occurs on the network red Tx Rx LED indicator will bl...

Страница 13: ...l Port of RS 232 RS 422 RS 485 Connect the serial data cable between the converter and the serial device Follow the setup procedure to configure the parameters of the converter see the following chapters RS 232 RS 422 485 ...

Страница 14: ...x Green LED Network signal receiving indicated when receive any signal form network the LED will flash Tx Red LED Network signal transforming indicated when transmit any signal to network the LED will flash LAN LED On line indicated when converter link to LAN then the LED will keep on 100M Green LED 10M Red LED ...

Страница 15: ...ton then turn on the power and waiting for 3 seconds Converter will reset to factory default Terminator There is terminator resistor built in If the switch 1 2 are set in ON position 120 Ohm resistor is connected between the signals Reset Button Terminator ...

Страница 16: ...16 Wiring Architecture RS 232 Wiring Architecture ...

Страница 17: ...tioned above and the LED indicators are as shown the converter is installed correctly You can use the Setup Tool EXPERTDAQETM exe to setup the IP Address To proceed the advanced parameters setup please use a web browser IE or Netscape to continue the detailed settings ...

Страница 18: ...s This chapter introduces the method to configure the device server s IP address For more details about network settings see Web Console Configuration in next sub section For quick setup of converter We suggest you to reference Quick Installation Guide manual The following topics are covered in this chapter Device Management Utility Menu View Menu Config ...

Страница 19: ... The Setup Tool only can setup one converter at a time Thus if there are more than one converter on the network please shut down or disconnect other converters Otherwise the ExpertDAQETM can not detect the converter Other similar issues you may reference to Q A in Appendix A Due to the nature of broadcast UDP packets ExpertDAQETM has following characteristics Broadcast packets aren t limited by su...

Страница 20: ...updated information Note Always run the View Refresh after any data change Exit Exit from the program ExpertDAQETM Config Moving the mouse cursor onto the desired device that displaying in information window Clicking the left button of mouse to invoke the ExpertDAQETM Config ...

Страница 21: ...of security it allows configuration only when device s setup password is empty Assign an IP Address with the same Subnet Mask of your computer avoiding any IP conflict with other network devices When you press Setup button the IP address will be refreshed in 2 3 seconds ...

Страница 22: ...ed Press Alt Enter or select Device Settings in the Config menu will open a new window in browser to login into the device Alternatively if the IP address of the converter is already known you can connect to the converter directly by providing its IP address in the URL field of browser The following topics are covered in this chapter Controller Status The Login Page Field Description Controller Se...

Страница 23: ...ss In the browser URL field set the IP address of device directly To enter the Controller Status page please follow the steps below Open your browser This chapter will use IE as an example In the browser URL field type the IP address of the converter directly and press ENTER The IP address is what you set using the Device Management Utility The Controller Status page will be shown see Figure 3 6 F...

Страница 24: ...tory default is empty However it is not recommended to leave it empty in field operation If you could not login it means you have to key in the password If you do not know the password you can turn off the power and then use any point tip to press Reset button and hold it to turn on the power The password will be reset to the factory default as empty EX 9132 2 TCP IP converter uses the same passwo...

Страница 25: ...ssword in the Password field and click the Login button in the Controller Status page then the Controller Setup page will appear see Figure 3 7 Note If you forget the password or can t login successfully please contact the manufacturer directly Figure 3 7 ...

Страница 26: ...y an ISP or the internal network administrator please inquire of them that information and type it correctly If DHCP client mode is enabled and there s a DHCP server on the network this field will be assigned by DHCP server automatically Gateway address Gateway or Router IP address Gateway is a device which connects local network to external network If you need to communicate with other networks o...

Страница 27: ... protocol use TCP port 80 for communication If the field is changed to 81 the port 80 will be reserved for user s own Web To enter the browser setup page http x x x x 81 should be typed for socket port 81 and http x x x x for socket port 80 where x x x x is the converter s IP address Destination IP address The server IP address and socket port would be connected in TCP Client and UDP mode for a ce...

Страница 28: ... input buffer is full or the converter detects a 10 character packet gap and no more character arrived The block waiting time is extended to avoid the splitting of the complete packet Device ID User assigned ID number for the converter Available ID is 0 65535 Report device ID when connected In TCP mode if this parameter is enabled every time when the socket is connected EX 9132 2 TCP IP converter ...

Страница 29: ...uld specify different port number for each serial port Socket type TCP Server TCP protocol passive open to be connected from the TCP clients TCP Client TCP protocol active open connect to the TCP server UDP Client UDP protocol connectionless Interface RS232 TxD RxD for data stream no flow control RS232 RTS CTS TxD RxD for data stream RTS CTS for flow control RS232 RTS CTS DTR DSR TxD RxD for data ...

Страница 30: ...sed for the serial communication However you should specify different port number for each serial port Socket type TCP Server TCP protocol passive open to be connected from the TCP clients TCP Client TCP protocol active open connect to the TCP server UDP Client UDP protocol connectionless Interface RS485 Half duplex Half duplex RS 485 interface RTS for driver enable disable RS422 Full duplex Full ...

Страница 31: ...5 seconds to complete the whole process and a new login page will be presented see Figure 3 1 Figure 3 8 You can re login and check if all parameters have been correctly saved If everything is ok you can close the browser now Note If the domain of the converter is different from that of the computer running the browser the login page won t appear unless the converter s Gateway Address has been cor...

Страница 32: ...tings to factory default A 1 Turn off the power of the converter 2 Press the reset button of the converter 3 Turn on the power of the converter and wait for 3 seconds 4 The password will reset to the factory default empty B 1 Log in the web page 2 Press the reset button of the converter 3 Select the update button 4 After Tx Rx light flashing then unclasp the reset button 5 The password will reset ...

Страница 33: ...indows 95 98 ME XP 2000 The Hyper Terminal utility should be installed on your PC see Figure 4 1 It can be found in your Windows installation CD The wiring architecture is similar to RS 232 Wiring in chapter 2 and the Serial Device is replaced by the PC s COM 1 The same PC also plays the roll of the Remote Host The following topics are covered in this chapter Hyper Terminal for TCP IP WinSock Hype...

Страница 34: ...34 Hyper Terminal for TCP IP WinSock Initiate a Hyper Terminal from the Start Menu in Windows see Figure 4 1 give a terminal name choose an icon and press OK button see Figure 4 2 Figure 4 1 Figure 4 2 ...

Страница 35: ... 4 3 After OK button is pressed Figure 4 4 appears Enter the converter s IP address e g 192 168 0 10 at the Host address field and the Socket port number set for the Serial Port 1 at the Port number field e g 4660 The Socket type of the Serial Port 1 should be TCP Server Figure 4 4 ...

Страница 36: ...36 After OK button is pressed Figure 4 5 appears If the Hyper Terminal connects with the converter successfully the time clock at the left lower corner Connected hh mm ss will start counting Figure 4 5 ...

Страница 37: ...Port of the converter 9600 N 8 1 Figure 4 3 Data Transmission When all steps described above are finished type any characters on the COM Port Terminal and check if the typed characters are also displayed on the TCP IP Winsock Terminal Alternatively check if the characters typed on the TCP IP Winsock Terminal are also displayed on the COM Port Terminal If yes then all settings are correct and the c...

Страница 38: ...verter Please refer SYS LED 2 2 2 Network cable is properly connected between the converter and the Hub Please refer LAN LED 3 Close Windows or antivirus program firewall Please refer Device Management Utility of EXPERTDAQETM Q Why can t I use IE to setup the converter A Please check if the network domain of your PC is the same as that of the converter ...

Страница 39: ... and Cable Wiring DC Power outlet RJ 45 Pin Assignment RS 232 Pin Assignment The pin assignment scheme for a 9 pin male connector on a DTE is given below PIN 1 DCD PIN 2 RXD PIN 3 TXD PIN 4 DTR PIN 5 GND PIN 6 DSR PIN 7 RTS PIN 8 CTS PIN 9 X ...

Страница 40: ...Assignment The pin assignment scheme for a 4 pin RS 422 is given below PIN 1 T PIN 2 T PIN 3 R PIN 4 R RS 485 Pin Assignment The pin assignment scheme for a 4 pin RS 485 is given below PIN 1 X PIN 2 X PIN 3 D PIN 4 D 1 2 3 4 ...

Отзывы: