background image

BACKUP

 

RELIEF

 

BELT

 

USER

 

MANUAL

 

 

Ver.

 

1.0

 

Unikia

 

AS

 

Sandakerveien

 

24c,

 

Bygg

 

c1,

 

0473

 

Oslo,

 

Norway

                                             

7

 

 

10

 

Technical

 

Specifications

 

WARRANTY

 

COMPANY

 

SHALL

 

NOT

 

BE

 

LIABLE

 

IN

 

ANY

 

EVENT

 

FOR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES.

 

Unikia

 

(“Company”)

 

warrants

 

the

 

Backup

 

Belt

 

(“Product”)

 

is

 

free

 

of

 

defects

 

in

 

materials

 

and

 

workmanship.

 

This

 

warranty

 

shall

 

remain

 

in

 

effect

 

as

 

per

 

the

 

legislation

 

of

 

the

 

country

 

in

 

which

 

the

 

unit

 

was

 

purchased.

 

11

 

Safety

 

information

 

INDICATIONS

 

FOR

 

USE

 

For

 

temporary

 

relief

 

of

 

pain

 

associated

 

with

 

sore

 

and

 

aching

 

muscles

 

in

 

the

 

lower

 

back

 

due

 

to

 

strain

 

from

 

exercise

 

or

 

normal

 

household

 

and

 

work

 

activities.

 

SAFETY

 

CONTRAINDICATIONS

 

Do

 

not

 

use

 

the

 

TENS

 

treatment

 

on

 

this

 

device

 

if

 

you

 

have

 

a

 

cardiac

 

pacemaker,

 

implanted

 

defibrillator,

 

or

 

other

 

implanted

 

metallic

 

or

 

electronic

 

device.

 

Such

 

use

 

could

 

cause

 

electric

 

shock,

 

burns,

 

or

 

electrical

 

interference

 

or

 

death.

 

 

 

Technical

 

specifications

 

Channels:

 

Single

 

channel

 

Waveform:

 

Asymmetric

 

biphasic

 

square

 

pulse

 

Pulse

 

Amplitude:

 

0

 

~110

 

mA

 

=

 

0

 

~

 

55

 

volts,

 

adjustable

 

(at

 

500

 

ohm

 

load)

 

Pulse

 

Frequency:

 

(Hz)

 

5

120

 

Pulse

 

Width:

 

(

μ

s)

 

120

 ‐ 

240

 

Timer

 

Control:

 

(mins)

 

20

 

mins

 

for

 

heat,

 

60

 

mins

 

for

 

tens

 

Power

 

Supply:

   

Lithium

polxmer

 

rechargeable

 

battery

   

Remote

 

Control:

 

One

 

(1)

 

CR2016E

 

Lithium

 

battery

 

Size

 

(D

 

x

 

W

 

x

 

H):

 

18

 

mm

 

x

 

191

 

mm

 

x

 

90

 

mm

 

Weight

 

(including

 

battery):

 

Mainunit

 

200g,

 

remote

 

17g

 

Safety

 

Standards:

 

CE,

 

R&TTE,

 

EN300220

2,

 

EN301489

3

 

EMC:

 

EN60601

1

 

Safety:

 

EN60601

1

2

 

Made

 

in

 

China

 

Содержание 002

Страница 1: ...kerveien 24c Bygg c1 0473 Oslo Norway Product Name BACKUP BELT Model Number 002 Company name EXPAIN AS Address Karl Johans gate 13 0154 Oslo Norway Contact Name Thomas Jakobsen Telephone number 47 970...

Страница 2: ...rt functionality 2 5 TENS functionality 3 APPLYING THE GEL PADS TO THE MAIN UNIT 3 HOW DOES IT WORK 4 TREATMENT RECOMMENDATIONS 4 CONDUCTING A TENS TREATMENT 4 6 HEAT functionality 5 CONDUCTING A HEAT...

Страница 3: ...ere the gel pads are placed b Electronics housing 4 USB cable Charger 5 Gel pads 6 Manual CONTROLS 7 Main unit On Off 8 Main unit Indicator Light 9 Remote unit On Off 10 TENS On button 11 TENS Off but...

Страница 4: ...t the charger is compatible to the mains in your current location Then connect the main unit The main unit indicator light will flash green every 5th second during charging The unit is fully charged a...

Страница 5: ...ng belts and pull them until you feel you have desired support Fasten with the Velcro Right hand side goes over the left hand side here too 5 TENS functionality Before using the TENS functionality of...

Страница 6: ...e the protective liners from the skin side of the gel pads by slowly peeling the liner diagonally from an inside corner to the opposite outside corner Important Avoid contact of the gel pad with other...

Страница 7: ...yellow for 10 seconds to indicate a heat treatment has started The heating temperature is 42 C It will take a bit of time before you can feel the heat after activation The unit will have enough batter...

Страница 8: ...ot Note The is facing upward Reverse the process to close the remote 9 Maintenance and storage Clean the device using a damp cloth and mild soap Gently wipe clean The right left inner belts can be was...

Страница 9: ...rk activities SAFETY CONTRAINDICATIONS Do not use the TENS treatment on this device if you have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic device Such use co...

Страница 10: ...Do not use the device s TENS treatment over or in proximity to these skin conditions abnormal skin skin that is not intact uncleaned unhealthy open wounds rashes swollen red infected inflamed areas sk...

Страница 11: ...2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable GUIDANCE AND MANUFACTURER S DECLARATION ELECTROMAGNETIC IMMUNITY The Backup Belt is intended for use in the electr...

Страница 12: ...fied below The customer or the user of the Backup Belt should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Con...

Страница 13: ...relocating the Backup Belt Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMEN...

Страница 14: ...ncy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a...

Отзывы: