background image

12

MANUGENETOP5xx UniOP 
Operating Instructions
VER 1.07

 Model

 

                eTOP512 

                                   eTOP513

 

 Display / Backlight

 

           TFT Color / LED                              TFT Color / LED 

 
 Colors

 

                     64K 

                                       64K 

 
 Resolution

 

                 800X600 

                                   1280x800 

 Diagonal (inches)

 

                     12.1” 

                                13.3” widescreen

 Dimming

 

                      yes 

                                       yes 

 User memory fl ash

 

                   256MB 

                                     256MB 

 SD card slot 

                      yes   

                                       yes 

 Recipe memory

 

Yes. Flash memory storage             Yes. Flash memory storage

 

limited only by available                  limited only by available

 

memory 

                  memory

 Serial Port

 

           RS-232,RS-485                             RS-232,RS-485 

 

      RS-422 DB9 female                         RS-422 DB9 female 

 

     software confi gurable                      software confi gurable

 Ethernet port

 

2   10/100 Mbit with integrated        2   10/100 Mbit with integrated                                 

 

     switch 

                        switch   

 USB port

 

2 Host interface, 1 version 2.0,

       

2 Host interface, 1 version 2.0,

 

 

       1 version 2.0 and 1.1                        1 version 2.0 and 1.1

 Expansion slot

 

         2 

  

Optional Plugin 

             

                2 

  

Optional Plugin 

 Battery

 

              rechargeable                                  rechargeable 

 Real Time Clock

 

                     yes 

                                       yes 

 Voltage

 

                10-32Vdc (

*

)                                    10-32Vdc (

*

 Current rating (at 24VDC)

 

                     1.2A 

                                      1.2A 

 Weight

 

                     2.8 Kg 

                                      2.8 Kg 

Technical Data

(

*

) For applications requiring compliance with EN 61131-2 and specifi cally in reference to 10 ms voltage dips, the 

minimum power supply voltage is 18Vdc.

Содержание UniOP eTOP 500 Series

Страница 1: ...Exor International S p A MANUGENETOP5xx UniOP Ver 1 07 UniOP eTOP Series 500 Operating Instructions Basic User s Manual for eTOP Series 500 Touchscreen Products...

Страница 2: ...hout notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation it...

Страница 3: ...Data 10 4 1 Dimensions 14 4 2 Installation Environment 16 4 3 Installation Procedure 17 5 Connections 18 5 1 Serial Port 20 5 2 Ethernet Port 21 5 3 Optional plugin module 22 6 Power Supply Grounding...

Страница 4: ...to the following models eTOP504 Operator interface with TFT color 4 3 display touchscreen eTOP506 Operator interface with TFT color 5 7 display touchscreen eTOP507 Operator interface with TFT color 7...

Страница 5: ...divided into three levels of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure to observe safety rules and...

Страница 6: ...nguages to meet global requirements Far East languages are supported Tools available in JMobile Studio support easy third party translations and help reducing development and maintenance costs of the...

Страница 7: ...ial in measures are taken in order to ensure conformity to EN 61000 6 3 The products are in compliance with the Restrictions on Certain Hazardous Substances RoHS Directive 2002 95 EC In compliance wit...

Страница 8: ...pulses per axis EN60068 2 27 Protection class IP66 front panel EN 60529 The front face of the UniOP unit installed in a solid panel has been tested using conditions equivalent to the standards shown...

Страница 9: ...ring some yellowing and brittleness may be present see Note 2 Touch screen reliability 1 milion operations Note 1 Extended use in environments where the surrounding air temperature is 40 C or higher m...

Страница 10: ...422 DB9 female RS 422 DB9 female software configurable software configurable Ethernet port 2 10 100 Mbit with integrated 2 10 100 Mbit with integrated switch switch USB port 1 Host interface 2 Host in...

Страница 11: ...5 RS 422 DB9 female RS 422 DB9 female software configurable software configurable Ethernet port 2 10 100 Mbit with integrated 2 10 100 Mbit with integrated switch switch USB port 2 Host interface 1 ve...

Страница 12: ...85 RS 422 DB9 female RS 422 DB9 female software configurable software configurable Ethernet port 2 10 100 Mbit with integrated 2 10 100 Mbit with integrated switch switch USB port 2 Host interface 1 v...

Страница 13: ...by available memory Serial Port RS 232 RS 485 RS 422 software configurable Ethernet port 2 10 100 Mbit with integrated switch USB port 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 Expansion s...

Страница 14: ...14 MANUGENETOP5xx UniOP Operating Instructions VER 1 07 4 1 Dimensions Technical Data eTOP504 MODEL A B C D E F 149mm 5 86 109mm 4 29 136mm 5 35 96mm 3 78 56mm 2 40 4mm 0 16 Cut out...

Страница 15: ...287mm 11 3 336mm 13 22 336mm 13 22 392mm 15 43 147mm 5 79 147mm 5 79 232mm 9 13 267mm 10 51 267mm 10 51 307mm 12 08 176mm 6 90 176mm 6 90 276mm 10 86 326mm 12 83 326mm 12 83 381mm 15 136mm 5 35 136mm...

Страница 16: ...the front panel protection classifications proper installation procedure must be followed the borders of the cutout must be flat screw up each fixing screw until the plastic bezel corner get in conta...

Страница 17: ...Operating Instructions VER 1 07 4 3 Installation Procedure Place the fixing brackets as shown in figure Fig 4 3 Fig 4 3 CAUTION Screw each fixing screw until the bezel corner gets in contact with the...

Страница 18: ...MANUGENETOP5xx UniOP Operating Instructions VER 1 07 5 Connections 1 Serial Port 2 2x Ethernet Port 3 USB Port 4 Power Supply 5 Expansion slot for Plugin module 6 SD Card Slot Fig 5 1 Connections eTOP...

Страница 19: ...19 MANUGENETOP5xx UniOP Operating Instructions VER 1 07 1 Serial Port 2 2x Ethernet Port 3 2x USB Port 4 Power Supply 5 2x Expansion slot for Plugin module 6 SD Card Slot Fig 5 2 Connections eTOP5xx...

Страница 20: ...232 RS 422 RS 485 Pin Description 1 GND 2 3 CHA 4 CHB 5 6 5V output 7 CHB 8 CHA 9 The serial port is software programmable Make sure you select the appropriate interface in the programming software Th...

Страница 21: ...nstructions VER 1 07 5 2 Ethernet Port 1 8 OFF Valid link has NOT been detected ON Valid link has been detected Connections ON No activity BLINKING Activity The Ethernet port have two status indicator...

Страница 22: ...ugin module multiple modules configurations are possible Slot 2 and Slot 4 are available only if plugin module has the bus extension connector Each slot carries three communication channels 1 serial i...

Страница 23: ...LCM05 CODESYS V2 License 1 Y PLCM06 Profibus DP 1 SPI N PLIO03 Multifunction I O 1 SPI N PLIO06 Compact I O 2 SPI N Max modules refers to max number of modules can be plugged into the HMI all slots If...

Страница 24: ...ps identify the ground connection Also connect to ground the terminal 3 on the power supply terminal block The power supply circuit may be floating or grounded In the latter case connect to ground the...

Страница 25: ...is maintained by the battery hardware real time clock date and time Charge At first installation must be charged for 48 hours When the battery is fully charged it ensures a period of 3 months of data...

Страница 26: ...puter running JMobile Studio software package the panel must be in Configuration mode to be programmed UniOP 500 series units are programmed via the Ethernet interface The software package JMobile is...

Страница 27: ...the picture below it is showed the version of the Main OS component System Settings has two operating modes User Mode and System Mode The difference between them is only in the number of available opt...

Страница 28: ...t at power up default settings are normally ok for all the units Download Configuration OS allows to check current version and upgrade the back up operating system see below in the next chapter for ad...

Страница 29: ...9 MANUGENETOP5xx UniOP Operating Instructions VER 1 07 11 LED Indicator on Front Panel The table below shows the symbol of the LED indicator dedicated to special functions LED Indicator on Front Panel...

Страница 30: ...30 MANUGENETOP5xx UniOP Operating Instructions VER 1 07 12 Unpacking and Packing Instructions Unpacking and Packing Instructions to repack the unit please follow the instructions backwards...

Отзывы: