background image

UK  |  

7

3112001_RSV_UK

Warning

To minimise the risk of fire, electric shock, personal injury 

and/or damage to the product please observe the following:

•   Please always read the manual and only use the product in accordance with the 

manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.

• 

 All installations must be carried out by properly qualifi ed personnel in accordance with 

national legislation and regulations.

• 

This product must be earthed. Get assistance from an qualifi ed electrician when in doubt. 

• 

The chimney fan must always remain switched on when the fireplace is in use.

• 

Ensure that the chimney has been swept before mounting the fan to avoid chimney fires.

•   Prior to servicing the product, disconnect the power and ensure that it cannot accidentally 

be reconnected.

• 

 Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is 

installed.

•   If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please 

ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-

ved, a smoke alarm must be installed in the same room as the heat appliance.

•   Note! Fans serving biomass boilers must be cleaned more often due to extensive residue/

soot building. It is essential that a regular inspection and cleaning schedule is implemen-

ted, especially in the early days of usage, to experience how often regular inspections and 

cleaning should be carried out.

UK

Your energy. 

Optimized.

Product information

An Exodraft RSV chimney fan is designed with vertical discharge.

The fan must be installed on top of a chimney and creates a negative pressure (suction) along the full 

length of the flue.

The fan can be used in connection with all types of fuel burning appliances and is especially well-suited to 

appliances burning solid fuel, such as wood-burning fireplaces and stoves and biomass or solid-fuel boilers.

The fan is part of an Exodraft system and should be connected to an Exodraft controller for optimal effect.

Incorrect firing may result in problems with soot, chimney fires, etc. which might damage the product. 

Please check out this site for advice about lighting and maintaining a fire:

www.exodraft.com

Scope of supply

•  Exodraft RSV chimney fan
•  Mineral wool mat for vibration-free mounting
•   Packet with location brackets, safety wire, bolts and nuts  

(wing screws included - to be used where allowed)

•  Armoured hose
•  Installation manual and user instructions

Accessories and spare parts

The table below shows the accessories and spare parts available for the RSV-models.

Accessories*

Spare parts

Flanges (for steel chimneys)

Motors

Cover Plates (for steel and brick chimneys)

Impellers and axial vanes

RSD - Dilution bolts (for brick chimneys)

Mineral wool mats

Rainshield

SVD-RS - Vibration dampers (for flanges on steel chimneys)

Capacitors

*This manual does not describe the specific use of accessories. We refer to the separate manuals for such components. 

 

For more details contact your Exodraft dealer.

Содержание RSV

Страница 1: ...Your energy Optimized Chimney Fan RSV UK Read and save these instructions...

Страница 2: ......

Страница 3: ...ansportation safety bracket 13 Minimum distance 14 Installation onto a brick chimney 15 Installation onto a steel chimney 17 Multiple fans on chimney 20 Electrical installation 21 Isolation switch 21...

Страница 4: ...waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste How to use this manual This manual has been prepared based on th...

Страница 5: ...ks a dangerous situation that in the worst case scenario can cause serious personal injury or signi cant damage to the product Electricity hazard High Voltage Marks a situation in which caution is adv...

Страница 6: ...efore mounting the fan to avoid chimney res Prior to servicing the product disconnect the power and ensure that it cannot accidentally be reconnected Exodraft always recommends the use of a smoke alar...

Страница 7: ...k out this site for advice about lighting and maintaining a fire www exodraft com Scope of supply Exodraft RSV chimney fan Mineral wool mat for vibration free mounting Packet with location brackets sa...

Страница 8: ...sonnel Exodraft reserves the right to change these guidelines without prior notice The warranty and liability does not cover instances regarding personal injury or damage to property or the product th...

Страница 9: ...distance greater than 2 5 metre away from the fan if installed correctly Further information about sound levels available in our technical brochure datasheet The RSV fan has been designed to tolerate...

Страница 10: ...5 250 100 RSV315 41 1400 1 x 230 1 80 0 37 37 380 580 465 315 115 RSV400 41 1400 1 x 230 2 60 0 60 47 430 650 525 400 130 RSV400 42 1720 3 x 400 3 50 0 75 52 460 650 525 400 130 RSV450 42 1720 3 x 400...

Страница 11: ...xial vane centrifugal impeller 6 Safety hinge 7 Safety mesh 8 Handle 9 Screws to fasten top and bottom section Alternatively use supplied wing screws where conditions allow 10 Armoured cable and conne...

Страница 12: ...ormally operate in a relatively stable environment where no major pressure fluctuations occur However to secure an optimal use of the Exodraft system speed adjustments and adjustment of air intakes ar...

Страница 13: ...ording to the manufacturer s instructions Transportation safety bracket Do not forget to remove the transport safety bracket located near the impeller and check that the axial vane impeller turns free...

Страница 14: ...vertically Be aware of national law and building regulations Minimum distance The minimum distance to flammable materials must be at least 500 mm national legislation must be observed RSV og GSV og RS...

Страница 15: ...temperature sensor is to be installed with the chimney fan cut a groove in the mineral wool mat that is big enough for the sensor 20 mm 20 mm 3 Mount and fasten the location brackets to the underside...

Страница 16: ...asily accessible when servicing the fan The armoured cable should be connected into the underside of the isolator and up into the switch via the cable gland R S V o g G S V o g R S V G 7 Before taking...

Страница 17: ...of the hole in the flange 2 Then cut a hole in the mineral wool mat that matches Note that there must always be a minimum of 20 mm of mat surface at any point around the circumference of the hole 20 m...

Страница 18: ...an with the use of the vibration dampers supplied with the flange Be aware that the washers flat and hex nuts must be mounted inside the bottom part of the RSV model RSV og GSV og RSVG 5 The fan assem...

Страница 19: ...S V o g R S V G 7 Before taking the fan into operation please make sure that the nuts in the location brackets have been tightened the safety wire has been fastened to the fan and chimney the safety...

Страница 20: ...emely important that the fans are of the same model and size and they must be controlled in tandem by one motor speed control A similar approach should be taken if the flue size exceeds the fan base d...

Страница 21: ...y Directive a chimney fan must always have an isolation switch fitted The isolation switch must comply with national wiring standards and it must be ordered separately as it is not part of the standar...

Страница 22: ...from the fireplace opening When the fire has caught on reduce the speed of the chimney fan to a point where it still removes the flue gases safely but without quenching the flames Remember this settin...

Страница 23: ...fessional chimney sweep Note The motor in the fan has ball bearings that are sealed lifetime lubricated and maintenance free Should replacement of the bearings be required this should be carried out b...

Страница 24: ...the axial vane impeller stick Check capacitor and replace if necessary Clean the fan The fan seems to work fine but there is not enough draught The fan may be undersized The capacitor may be worn out...

Страница 25: ...owing regulations The Supply of Machinery Safety Regulations 2008 Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regulations 2016 Langeskov 01 11 2022 Managing Director And...

Страница 26: ...lvitys koskee on seuraavien standardien mukainen Sem eru me talin i sta festingu Pessari eru i fullu samr mi vi eftirtalda sta la Sono stati fabbricati in conformit con le norme degli standard seguent...

Страница 27: ......

Страница 28: ...fo exodraft no www exodraft no UK Exodraft Ltd 24 Janes Meadow Tarleton GB Preston PR4 6ND Tel 44 0 1494 465 166 Fax 44 0 1494 465 163 info exodraft co uk www exodraft co uk DE Exodraft a s Niederlass...