background image

Figure 1

1.

Front of the unit

3.

Upper handle

2.

Upper handle mounting
tab

Install the LPG Tank Bracket

1. Position the LPG tank bracket on top of the tank

and handle support so the lever is on the operator’s
LH side.

2. Install the four 5/16 x 3/4 inch carriage bolts

through the slots in the LPG tank bracket and tank
support. Secure with four flanged 5/16 inch nyloc
nuts.

Install the LPG Fuel Tank

1. Remove the LPG tank from the carton.

2. Have the tank filled by trained and qualified

personnel.

CAUTION

Under no circumstances should propane tanks
filled beyond 80% capacity be used in service.

The use of overfilled tanks may result in the
release of highly concentrated and extremely
flammable liquid propane. Refer to the Safety
section.

3. Carefully install the filled tank in the LPG tank

bracket. Align the slot in the base of the tank with
the indexing tab at the front of the tank support as
shown in Figure 2.

Figure 2

1.

Tank slot

3.

LPG tank

2.

Mounting tab

4. Latch the bracket and make sure the tank is securely

fastened to the mower. The latch may require
adjustment to fit the tank tightly.

5. Carefully connect the fuel hose; the threads are LH.

Make sure the hose is not kinked.

6. Slowly open the fuel valve to equalize the pressure in

the tank. If the fuel valve is opened too quickly, the
pressure relief valve is equipped with a back pressure
check valve that will shut off the fuel supply. If this
happens, close the fuel valve completely and wait five
seconds. Slowly open the fuel valve.

7. Check for leaks as described in the

Inspection

section of the Operator’s Manual.

Attaching the Throttle Cable

1. Route the throttle cable along the right side of the

upper handle, under the fuel tank support, and
position the cable on the

left

side of the engine.

2. Position the throttle control lever (located on the

console) in the full throttle position. You will feel a
detent when the throttle lever is pushed towards the
upper end of the slot.

3. Attach the inner wire of the throttle cable to the top

hole in the throttle control lever as shown in Figure 3.

4. Loosen the clamp, install the throttle cable on the

bottom side of the clamp, and pull on the cable to
move the throttle linkage to the full throttle position.
Tighten the cable clamp screw.

2

Содержание TURF TRACER X-SERIES LP Operators

Страница 1: ...arranty registration form and place keys into literature pack Literature Pack Part Description Qty Use Manual Operator s 1 Read before operating the machine Manual Engine Operator s 1 Read before operating the machine Uncrating the Unit 1 Leaving the unit on the pallet place the upper handle assembly and the LP tank bracket at the rear of the machine 2 Remove the bolt bag from under the mower deck...

Страница 2: ...ned to the mower The latch may require adjustment to fit the tank tightly 5 Carefully connect the fuel hose the threads are LH Make sure the hose is not kinked 6 Slowly open the fuel valve to equalize the pressure in the tank If the fuel valve is opened too quickly the pressure relief valve is equipped with a back pressure check valve that will shut off the fuel supply If this happens close the fu...

Страница 3: ... engagement lever tab and the hairpin on the outside Figure 4 1 Lower PTO engagement linkage 2 Jam nut 3 Turnbuckle 4 Upper PTO engagement linkage 3 With the PTO engaged adjust the linkage length by loosening the locknut on the turnbuckle and adjusting the turnbuckle so that the bolt on the bellcrank and the indicator arm align with each other within 1 16 inch 1 6 mm Figure 5 Tighten locknut again...

Страница 4: ...x 1 3 4 inch hex cap screw and a 5 8 18 inch nyloc nut on each side and tighten This will give an approximate setting for drive lever linkages Figure 6 Right Hand Side of Unit Shown 1 Drive lever linkage 2 5 16 18 inch nyloc nut 3 Speed control lever in neutral 4 Drive levers in neutral 5 5 16 18 x 1 3 4 inch hex capscrew 6 3 8 24 inch LH jam nut 7 Hydro control arm weldment 8 Lower ball joint Adj...

Страница 5: ...rning Battery posts terminals and related accessories contain lead and lead compounds chemicals known to the State of California to cause cancer and reproductive harm Wash hands after handling Important The machine is shipped with a filled lead acid battery DANGER Charging the battery may produce explosive gasses Battery gasses can explode causing serious injury Keep sparks flames or cigarettes aw...

Страница 6: ...ake the tire circumferences match as closely as possible Greasing the Unit Note The unit is not greased at the factory 1 Lubricate fittings with NGLI grade 2 multi purpose gun grease Refer to the following chart and Figure 8 for fitting locations and initial pumps Lubrication Chart Fitting Locations Initial Pumps Number of Places Service Interval 1 Front Caster Wheel Bearings 12 2 Daily 2 Front Ca...

Страница 7: ...he HOT level shows the level of oil when it is at 225 F 107 C The COLD level shows the level of the oil when it is at 75 F 24 C Fill to the appropriate level depending upon the temperature of the oil For example If the oil is about 150 F 65 C Fill to halfway between the HOT and COLD levels If the oil is at room temperature about 75 F 24 C fill only to the COLD level Filling Out the Product Registr...