![Exlar Curtiss-Wright Tritex II Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/exlar/curtiss-wright-tritex-ii-series/curtiss-wright-tritex-ii-series_installation-and-service-manual_2450854021.webp)
Curtiss-Wright | TRITEX II AC 75 Rev. K PN61928 7/12/2022
20
Drive Specification for all Tritex II -75 mm 240 Volt Models
Drive Specifications
Input Voltage,
Bus and Logic
100 to 240 Volts AC n/-10% overvoltage.
Overvoltage Category II, Pollution Degree 2, Required
type of electrical supply system is TN.
External Power
Supply
(Optional)
24 V dc +/- 10% - Provides power for IO, Brake and
Logic, Class 2 or isolating source protected by 3A
maximum fuse 0.5 A dc max load
Enclosure
Rating
IP:66
Digital Inputs
SIO & Ethernet options: 8 – opto isolated, IA4 or CAN
option 4- opto isolated 12 to 30 Vdc for ON state, 0 to
1V dc for OFF state, common return at “I/O Power
Supply” “common” terminal Programmable functions
Digital Outputs
SIO & Ethernet options: 4 – opto isolated,
IA4 or CAN option 3- opto isolated 100 mA continuous,
short circuit protected, powered from “I/O Power
Supply” with 1V maximum drop from supply voltage,
programmable functions
Analog Input
0-10 Volts or +/- 10 Volts differential input, 13 bit
resolution, programmable as position, velocity or
torque command
Analog Output
0-10 Volts at up to 10 mA, 11 bit resolution,
programmable functions
Serial Interface
Optically isolated RS-485, Modbus RTU protocol,
38.4kbaud max
Commutation
Sinusoidal, 10kHz PWM
Position
Resolution
0.001 revolution (with analog hall feedback)
Accuracy
+ / - 0.002 revolution (with analog hall feedback)
Environmental
Ambient Temperature, charts below show ratings for
40° C Maximum Operating temperature range -20° to
65° C See de-rating chart for temperatures above 40°
C. For operation below -20°C contact Exlar
Applications Engineering. Storage Temperature -40°C
to 85°C. Operational Altitude is 2000 meters.
Содержание Curtiss-Wright Tritex II Series
Страница 10: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 9 UL Certificate of Compliance...
Страница 11: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 10...
Страница 14: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 13...
Страница 15: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 14...
Страница 18: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 17...
Страница 19: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 18...
Страница 46: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 45 Block Diagram of 24V IO and Logic Supply Connections...
Страница 73: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 72 ACCESSORIES Cables TTIOC xxx I O Cable...
Страница 74: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 73 T2IPC xxx Power Cable...
Страница 75: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 74 TTICO xxx Communications Cable...
Страница 77: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 76 Braking Resistor T2BR1...