background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

1                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 
 
 
 

ORCA-50 Handheld Data Terminal 

UHF Demo Manual V1.0 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Eximia Srl. 

www.eximia.it

 - www.rfidstore.it 

[email protected]

 

 

   

Содержание ORCA-50

Страница 1: ...ORCA 50 UHF Demo Manual V1 0 1 Eximia Srl www eximia it www rfidstore it ORCA 50 Handheld Data Terminal UHF Demo Manual V1 0 Eximia Srl www eximia it www rfidstore it mario difloriano eximia it ...

Страница 2: ...ctivation the tag operation 1 3 5 Select the tag operation 1 3 6 Access the label may return an error message 1 4 Inventory and access ISO 18000 6B tags 1 4 1 Inventory ISO 18000 6B tag 1 4 2 Access ISO 18000 6B tags 1 5 RF parameter settings 1 5 1 Set the RF output power 1 5 2 Set the radio frequency spectrum specification 1 5 3 Set the antenna connection to receive 1 5 4 Measure the return loss ...

Страница 3: ...ved for this document 1 UHF software operation and configuration 1 1 Start the UHF Demo software Click the UHF Demo icon to enter the connection interface select ttyS1 rk_serial serial port click on the immediate connection to enter the main interface The main interface for the ISO 18000 6C tag inventory interface ...

Страница 4: ...F RFID reader its performance directly determines the merits of the reader 1 2 1 Ordinary inventory Click the Start Stock button or trigger the trigger of the handset handle If the label is within the signal range the EPC data of the label will be uploaded immediately and updated in real time If you do not click on the end of the inventory or release the trigger the reader will keep the inventory ...

Страница 5: ... each inventory command The unit is milliseconds Total duration The total amount of time since the start of the inventory button was clicked The unit is milliseconds The list of tags in the EPC number list do not repeat the meaning of the fields in the list box is as follows ID The serial number of the data EPC The EPC number of the label PC Label protocol control word ID CNT The number of times t...

Страница 6: ...nti collision algorithm Set to 2 then each disk command to repeat the implementation of two anti collision algorithm and so on Custom Session parameters Click the Custom Session parameter check box Session ID and Inventoried Flag will become optional then click the Start button the reader will be a custom Session and Target inventory 1 3 Access ISO 18000 6C tags Click the Access Tag check box to a...

Страница 7: ...w The read tag needs to enter three parameters the label area to be read the start address and the data length Note that here the starting address and The data length units are WORD which is 16 bit double bytes When the parameter is set click the Read tab button It should be noted that the input parameters to meet the specifications of the label otherwise there will be an error When the operation ...

Страница 8: ... is that the write operation also need to provide access to passwords and write data to this information The password area is part of the electronic tag that stores the password password Including inactivation passwords and access passwords The inactivation password and the access password are 4 bytes Where the address of the inactivation password is 00H 03H in bytes the address of the access pass...

Страница 9: ...tag again to verify that the data is written correctly Note that the maximum write length is 32 Word 64 bytes 512bits 1 3 3 Lock the label operation The operation interface of the lock label is shown in the following figure The lock tag must be provided with an access password to proceed Note The original password lock is invalid it is recommended that users first modify the access password and th...

Страница 10: ...on tag is shown in the following figure The deactivation tag must provide an inactivation password and the inactivation password can not be 00 00 00 00 Therefore to destroy a label first change the contents of the password inactivation password by writing a tag command After killing tag is successful the following information is returned How many tags are displayed in the list as with all access t...

Страница 11: ...EPC number of labels to access operations this time you need to use the selected operation of the label function EPC matching function In the accompanying demo software operate as follows First save the label get all the EPC number And then go to the interface to access the tag select the EPC number to match As shown below When the selection is complete click the selected tab as shown below ...

Страница 12: ...you want to cancel the EPC match just click Cancel in the drop down menu and click the Select button As shown below 1 3 6 Access the label may return an error message In the process of access to the label operation if the operation is not correct there will be an error message then we listed some common operational problems Successful inventory but failed to access ...

Страница 13: ...t in the storage area another reason is that the RF energy is not enough access to the operating distance of the label is about the disk operating distance 60 to 70 so if this is the case please move the label closer to the antenna Access password is wrong The cause of this problem as described in the prompt is that the access password is set incorrectly There is no operational label error There a...

Страница 14: ...simultaneously identifies multiple tags 1 4 2 Access ISO 18000 6B tags Access to the leaflet ISO 18000 6B label can only be accessed Click the Access tab button to select the label to be operated in the UID list as shown in the following figure The next operation is relatively simple the user can operate on their own Note the following points The access operation must operate the label of the curr...

Страница 15: ...one byte of data can be queried at a time Locked byte operations are permanent and irreversible 1 5 RF parameter settings After successfully connecting the reader we need to set some of the most basic RF parameters the output power and spectral range The setting of the RF parameters is set in the reader settings RF parameters page as shown in the following figure 1 5 1 Set the RF output power RF o...

Страница 16: ... for radio frequency spectrum There are two ways to set the reader s spectrum Method 1 Use the default frequency of the reader The default frequency of the reader can refer to the frequency parameter correspondence table in the communication protocol The reader supports a frequency range of 865MHz 868MHz 902MHz 928MHz Use the drop down boxes and buttons shown below to set the desired operating fre...

Страница 17: ...nction is read and write tags before checking whether the port is connected to the antenna if not connected then notify the user antenna is not connected Before using the user to open this function through the interface shown below to view set the interface of this function as shown below The sensitivity of the antenna detection is set by the user Antenna detection sensitivity is the antenna port ...

Страница 18: ...ng and writing labels for a period of time The operating interface for monitoring the temperature is as follows 1 6 2 Set the buzzer status The buzzer provides the user with the sound information of the reader s use status The user can turn the buzzer off or set it to sound every time the label is saved It can also be set to sound every time a label is read but this will result in a reduction in t...

Страница 19: ...the reader This interface is based on serial communication so regardless of the user s physical interface is RS 232 or TCP IP the reader is to follow the definition of this interface Demonstration program provides an important function is the serial port transmission records the user with the communication protocol documentation and demo program operation process of the actual serial data to compa...

Страница 20: ... to return to the software data Which manually send data function for users to debug serial port command to use it has automatically calculated check sum function In addition the accompanying documentation also includes the complete source code for this demo program for user reference so that applications based on this handheld device can be quickly developed ...

Отзывы: