Problems and Symptoms
Possible Cause
Solution
No Output voltage
No Indication
Poor battery condition or
battery connection loose
Use new battery or make
proper connections
No output voltage
Overload indication
Excess Load Applied
Reduce the excessive load
from the Exide Inverterz &
reset by ON/OFF Switch
No output voltage
All LED Blinking
Thermal shut down
Call the service support. There
is overheat problem in the
system
Mains LED Blinking with
Buzzer
Thermal Circuit Breaker Trip
Reset Thermal Circuit Breaker
Mains ON but Not Charging
UPS/ Normal Selection
switch may be in UPS mode
Check Mains voltage &
Selection of Normal / UPS
mode as per specified voltage
range
Mains ON but Not Charging
Bypass Switch may by in
Bypass Mode
It should be in Manual Mode
while Inverterz is OK