background image

2/16

1.  Product Information

 

1.1  Function........................................................................................................................... 3

 

1.2  Components .................................................................................................................... 3

 

1.3  Shipping........................................................................................................................... 4

 

2.  Specifications

 

2.1  Dimensions & Capacities................................................................................................. 5  

 

3.  Installation 

 

3.1  Positioning....................................................................................................................... 6

 

3.2  Floor or Roof Mounting.................................................................................................... 6

 

3.3  Ceiling Mounting.............................................................................................................. 7

4.  Wiring 

 

4.1  Electrical Requirements................................................................................................... 8

 

4.2  Wiring Diagram — BESF 146-180................................................................................... 8

5.  Duct Connection

 

5.1  Connection to Duct.......................................................................................................... 9

6.  Service & Maintenance

 

6.1  Cleaning Intervals.......................................................................................................... 10

 

6.2  Cleaning ........................................................................................................................ 10

 

6.3  Service........................................................................................................................... 10

7.  Troubleshooting

 

.............................................................................................................................................11

8.  Spare Parts

 

8.1  Parts Ordering ............................................................................................................... 12

9.  Warranty

 

9.1  Warranty ........................................................................................................................ 13

 

9.2  Warranty Disclaimer ...................................................................................................... 13

 

 

   

 

5.  This unit must be grounded.

How to use this manual

This installation manual does not contain any system design 

documentation.  System design documentation is available from any 

authorized EXHAUSTO representative.
Accessories, fans and variable frequency drives are not covered by 

this manual.  Please refer to these component’s individual manuals.

 

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

Caution: 

 Indicates an imminent hazardous situation 

which, if not avoided, may result in personal injury or 

property damage. 

Symbol Legend:

The following terms are used throughout this manual to bring attention 

to the presence of potential hazards or to important information 

concerning the product.

Danger: 

 Indicates an imminent hazardous situation which, 

if not avoided, will result in death, serious injury or 

substantial property damage.

1.  Use this unit in the manner intended by the manufacturer.  If 

  you have questions, contact the manufacturer at the address or 

  telephone number listed on the front of the manual.
2.  Before servicing or cleaning the unit, switch off at service panel 

  and lock service panel to prevent power from being switched on 

  accidentally.
3.  Installation work and electrical wiring must be done by a qualified 

  person(s) in accordance with applicable codes and standards.
4.  Follow the appliance manufacturer’s guidelines and safety 

  standards such as those published by the National Fire Protection 

  Associations (NFPA), and the American Society for Heating, 

  Refrigeration and Air Conditioning Engineers (ASHRAE), and the 

  local code authorities.

Содержание BESF 146

Страница 1: ...Parkway STE 180 Roswell GA 30076 770 587 3238 800 255 2923 Fax 770 587 4731 info exhausto com us exhausto com Installation Operating Manual READ AND SAVE THESE INSTRUCTIONS USA CAN 3001806 03 02 BESF...

Страница 2: ...aution Indicates an imminent hazardous situation which if not avoided may result in personal injury or property damage Symbol Legend The following terms are used throughout this manual to bring attent...

Страница 3: ...uction The ventilator housing is made of galvanized steel and insulated with fiber insulation The collars are fitted with silicone seals to assure a tight assembly The motor is a direct drive variable...

Страница 4: ...handled in a way to prevent damaging the collars and the ventilator housing Never operate the ventilator with the access door open To open access door loosen screws on latch handles and raise handles...

Страница 5: ...0 16 0 35 RPM 1600 Weight lbs 28 38 60 kg 13 17 27 Duct Connection E in 7 8 8 mm 177 200 200 Dimensions A in 13 60 14 57 16 15 mm 345 370 410 B in 11 62 12 60 13 98 mm 295 320 355 C in 7 88 9 26 9 26...

Страница 6: ...nd the shaft which can shorten the product life Never install the ventilator so the motor points down This will shorten the life 3 2 Floor or Roof Mounting To minimize the transfer of noise and vibrat...

Страница 7: ...proximately 80 See Fig 5 3 3 Ceiling Mounting If hung from the ceiling brackets with eye hooks not included must be installed as shown below in Fig 6 Ceiling bolts must be properly sized to be able to...

Страница 8: ...age 5 The ventilator can be equipped with a variable speed motor Fig 7 shows a typical wiring diagram for a BESF utilizing a Fan Speed Control Fig 7 To fan To power Black Black White White Red Green V...

Страница 9: ...es observed If transfer of vibrations is a major concern special vibration dampening connectors FLF should be installed These are available from EXHAUSTO If a duct is not connected a safety screen acc...

Страница 10: ...nside housing and the wheel with water containing a detergent 4 Dry all parts with a cloth 5 Close and secure the access door 6 Turn the fan on If necessary the blower wheel can be removed Prior to re...

Страница 11: ...wheel Motor capacitor has failed Please refer to section 1 1 Use Motor windings or bearings are failing Please refer to section 1 1 Use 7 Troubleshooting 11 16 What to do Resize ducts Clean and inspe...

Страница 12: ...dering spare parts please have the model number and part position number available 01 Motor 02 Impeller 03 Shaft extension 04 Support legs with vibration dampers 2 05 Motor housing plate outside housi...

Страница 13: ...STO s discretion The original end user of EXHAUSTO Chimney Fans Models RS and RSV qualifies for a 6 month Performance Guarantee If the user is not completely satisfied with the chimney fan it can be r...

Страница 14: ...14 16 Notes...

Страница 15: ...15 16 Notes...

Страница 16: ...1200 Northmeadow Parkway STE 180 Roswell GA 30076 770 587 3238 800 255 2923 Fax 770 587 4731 info exhausto com us exhausto com 3001805 03 02 BESF 146 BESF 160 BESF 180...

Отзывы: