Test Results
514
88000 Series
Summary (SyncE)
ESMC
Indicates the current (meter and value), average, minimum, and
maximum ESMC frame rate (including information and event frames)
received in frame/s. A fail verdict is also displayed beside the minimum
and/or maximum values when the ESMC frame rate is outside the range
while the Pass/Fail Verdict is enabled.
ESMC RX Rate
meter displays the current ESMC frame rate (including
information and event frames) in frame/s averaged over the last 11 frames
received. The pass/fail verdict is also displayed when enabled.
Note:
When the
Pass/Fail Verdict
and
ESMC Rate Threshold
check boxes are
selected (see page
), the green region is delimited from 0.8 to 10.2
frames/s corresponding to a
PASS
verdict. The red regions above and
beyond the threshold correspond to a
FAIL
verdict. There is neither green
nor red region when the Pass/Fail verdict is disabled.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...