Managing Results
Optical Spectrum Analyzer
283
Managing WDM Test Results
Results Tab
The results table shows channel results for the active trace. The results for
only the channels within the scan range will be displayed. The pass/fail
verdict for thresholds are also displayed in the results table. If the verdict is
fail for any parameter, its value will appear in red.
To view results:
From the main window, select the
Results
tab.
The following information related to the channels is displayed in the
Results
table:
³
P/F
: indicates Pass/Fail status of the channel.
: indicates Pass status.
: indicates Fail status, meaning at least one parameter failed.
³
Ch#
: indicates the channel number. Channel 1 corresponds to the first
channel found.
³
Name
: indicates the channel name as defined in the channel list.
³
Center wavelength/frequency
: indicates the spectral center-of-mass
for the peak in that channel.
³
Power (dBm)
: indicates the signal power for the selected channel
(excludes noise) (according to current calculation method, in dBm).
³
OSNR (dB)
: is the Optical Signal to Noise Ratio, given by Signal power
(according to the current calculation method, in dBm) minus Noise
(according to the current calculation method, in dBm).
Содержание FTB-5240BP
Страница 1: ...User Guide Optical Spectrum Analyzer for FTB 500 FTB 5240S 5240BP...
Страница 8: ......
Страница 14: ......
Страница 54: ...Setting Up the Instrument in WDM Mode 46 FTB 5240S 5240BP Defining Preferences 2 Select the Display tab...
Страница 110: ......
Страница 120: ...Setting Up the Instrument in Drift Mode 112 FTB 5240S 5240BP Defining Preferences 2 Select the Display tab...
Страница 181: ...Setting Up the Instrument in DFB Mode Optical Spectrum Analyzer 173 Defining Preferences 2 Select the Display tab...
Страница 190: ......
Страница 225: ...Setting Up the Instrument in EDFA Mode Optical Spectrum Analyzer 217 Defining Preferences 2 Select the Display tab...
Страница 240: ...Setting Up the Instrument in EDFA Mode 232 FTB 5240S 5240BP Setting Up EDFA Analysis Parameters 2 Select the General tab...
Страница 282: ...Testing DWDM Systems 274 FTB 5240S 5240BP Starting a Measurement Drift Mode DFB Mode...
Страница 283: ...Testing DWDM Systems Optical Spectrum Analyzer 275 Starting a Measurement Spectral Transmittance Mode EDFA Mode...
Страница 306: ...Managing Results 298 FTB 5240S 5240BP Managing WDM Test Results 3 Select the Include in calculation option...
Страница 372: ...Managing Results 364 FTB 5240S 5240BP Managing Spectral Transmittance Test Results 2 Press Global Parameters...
Страница 391: ...Managing Results Optical Spectrum Analyzer 383 Managing EDFA Test Results...
Страница 392: ...Managing Results 384 FTB 5240S 5240BP Managing EDFA Test Results 3 Select the Include in calculation option...
Страница 394: ...Managing Results 386 FTB 5240S 5240BP Managing EDFA Test Results...
Страница 407: ...Managing Results Optical Spectrum Analyzer 399 Managing Trace Files 2 Press New...
Страница 414: ...Managing Results 406 FTB 5240S 5240BP Managing Trace Files...
Страница 422: ...Managing Results 414 FTB 5240S 5240BP Generating Reports A sample WDM txt report is shown below...
Страница 423: ...Managing Results Optical Spectrum Analyzer 415 Generating Reports A sample Drift html report is shown below...
Страница 424: ...A sample Drift txt report is shown below...
Страница 425: ...Managing Results Optical Spectrum Analyzer 417 Generating Reports A sample DFB html report is shown below...
Страница 426: ...Managing Results 418 FTB 5240S 5240BP Generating Reports A sample Spectral Transmittance html report is shown below...
Страница 427: ...Managing Results Optical Spectrum Analyzer 419 Generating Reports A sample EDFA html report is shown below...
Страница 428: ......
Страница 434: ......
Страница 437: ...Troubleshooting Optical Spectrum Analyzer 429 About 2 Press About...
Страница 444: ......
Страница 446: ......
Страница 530: ......