EXENDIS B.V.
Impulse S6-S8
75
9.3 Only the green LED is blinking
If the yellow LED lights and the green LED is (slowly) blinking, (while the relay is audible
switching), this means, that the charger starts charging. After that the charger sees that
the voltage rises very fast en therefor stops charging and again starts charging. This
usually means that the battery has been worn out and has to be replaced.
9.4 The yellow and green LED’s are blinking
In case of a failure, both LED’s blink a number of times followed by one second rest.
This number indicates which failure has occurred.
Number of times the
LED’s blink followed by a
short rest
Failure description
Remedy
4
Temperature too low or
hardware problem
1)
5
Temperature too high
2)
1, 2, 3, 6, 7, 8
Other problem
3)
Remedy codes:
7) Move charger to a room with temperature above 0
°
C and restart the charging process.
If temperature is above 0
°
C and the failure report repeats itself, then you should
consult your supplier/dealer.
8) Allow the charger to cool down for some time and then the charging process should be
restarted. If the failure report repeats itself then you should consult your
supplier/dealer.
9) Consult your supplier/dealer.
10. CLEANING
AND MAINTENANCE
The charger and the cables can be cleaned with a damp cloth. Do not use aggressive
cleaning agents.
The charger is maintenance-free.
11. REPORTING SERVICE
When reporting the service department of your supplier/dealer you should always report
the following data:
i) Type of charger (IMPULSE S 6 / 8)
j) Which LED’s are lighting or which are not lighting?
k) When did you observe the failure report?
l) When was the charger taken into operation?