![ExelTech ICX Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/exeltech/icx/icx_installation-and-operation-manual_2449777007.webp)
Supplied with unit and a required part.
It is able to sense the temperature of a battery when charging. The
“
Float Voltage” will be automatically adjusted in order to avoid over-
charging a hot battery.
Will shut down the charging
function of the MCX/ICX if there is to much resistance between the
positive and negative battery connection indicating that the battery
is bad or that there is a bad connection.
Provided by a thermostatically controlled brushless fan
located on the front panel.
Located on the front panel, will be "ON” when
inverter is powered up, and DC power is available.
Produces an audible alarm if DC
input voltage falls to a level within 2% to 4% of the low limit of
inverter, or, if there is an over temperature condition.
Located on front panel; turns the inverter on and
off.
When the battery voltage exceeds
set limits, the inverter/charger will immediately and without warning
shut off. This will require the user to cycle the on/off switch to turn the
inverter back on. This fault can usually be attributed to a poor battery
connection or faulty battery.
When battery voltage falls to
within 5% of low line voltage, the LOW BAT/THERM buzzer will
sound. If the condition continues without reducing load to the
Inverter or adding charge to the battery, the inverter will shut off.
When voltage rises to approximately 90% of nominal battery voltage
the inverter will turn back on and the alarm condition will clear. The
inverter can be manually reset by cycling the on/off switch. This will
reset the protection circuit and turn the inverter on at any voltage
above minimum voltage.
EXTERNAL THERMISTOR:
BAD BATTERY PROTECTION:
COOLING:
DC POWER ON LED:
LOW BATT / THERM BUZZER:
ON/OFF SWITCH:
OVER VOLTAGE PROTECTION:
UNDER VOLTAGE PROTECTION:
.
.
.
.
.
.
.
.