56
Dual Modules (CmG-CmH)
Ratings
Parameter
Description
Module
Min
Nom /
Typical
Max
Output Voltage (V)
Output voltage range for which the module
channel is rated for operation
CmG (V1+V2)
3
24
30
CmH (V1)
3
5
6
CmH (V2)
3
24
30
Factory Setting
Accuracy (mV)
Maximum deviation from target output
voltage setting when CoolX is initially
configured.
All Mods
40
Output Current (A)
Maximum output current for which the
channel is rated for operation.
Co
o
lX600
CmG (V1+V2)
3
CmH (V1)
6
CmH (V2)
3
Co
o
lX1800
CmG (V1+V2)
4
CmH (V1)
10
CmH (V2)
4
Output Power per
Channel (W)
Maximum output power for which each
channel of the module is rated for
operation.
(Maximum output power to be derated
when CoolX is used in ambient
temperatures greater than 40
ᵒ
C
–
Appendix 2: Thermal Derating for
further details)
Co
o
lX600
CmG (V1+V2)
90
CmH (V1)
36
CmH (V2)
90
Co
o
lX1800
CmG (V1+V2)
120
CmH (V1)
60
CmH (V2)
120
Total Output Power
(W)
Maximum total output power for which
the module (both channels) is rated for
operation.
(Maximum output power to be derated
when CoolX is used in ambient
temperatures greater than 40
ᵒ
C
–
see
Appendix 2: Thermal Derating for
further details)
Co
o
lX600
CmG
120
CmH
120
Co
o
lX1800
CmG
200
CmH
180
Capacitive Loading
(mF/V
o
)
Maximum capacitive load of the module to
ensure monotonic startup (with no additional
load applied)
CmG (V1+V2)
6.6
CmH (V1)
13.2
CmH(V2)
6.6