Protective Limits
Parameter
Description
Module
Min
Nom /
Typical
Max
Current Limit (A)
Hiccup. Auto-Recovery
Co
o
lX600
CmE
27
29
30
CmF
13.5
14
15
Co
o
lX1800
CmE
39
41
43
CmF
19.5
20.5
21.5
Short-Circuit
Current Limit
(Arms)
Measured over 5 hiccup cycles
CmE
5
CmF
2.5
Power Limit (A)
Hiccup, Auto Recovery
Co
o
lX600
CmE
615
695
755
CmF
615
670
755
Co
o
lX1800
CmE
890
985
1080
CmF
890
985
1080
Overvoltage
Protection (V)
CoolX600: Shutdown, Latching
CoolX1800: Shutdown, Auto-Recovery
CmE
29
30.5
31.5
CmF
45.5
59
62
Sense Lead
Protection (V)
CoolX600: Shutdown, Latching
CoolX1800: Shutdown, Auto-Recovery
All Mods
7
Start-Up / Shut-Down
Parameter
Description
Module
Min
Nom /
Typical
Max
Turn-On Delay (ms)
Time from Application of Input AC to Output
Voltage Regulation (t1)
All Mods
640
800
Turn-Off Delay (ms)
From Loss of AC to Loss of Output Voltage
Regulation
–
Nominal Voltage (t2)
All Mods
16
20