Connect the unit to the main power, press the switch to the position of I : ON, the 
red operation indicator will light to indicate the heater is on and the heater will 
begin to radiate infrared heat. 

 

OPERATION INSTRUCTIONS

 

1.

  Plug in the device, and then press the switch to the position of I (refer to 

picture 1). The device will sound 1beep, one of the heat lamp indicators will 
flash (picture 1), the device is in standby mode and the unit won’t radiate any 
heat.  

PICTURE 1. 

 

2.

  Point the remote control directly to the receiver, press 

the “ON” button on remote, the device will sound 1 
beep and the unit will start to heat in high power mode 
(100% of the rated power) and all three heat lamp 
indicators will turn red. Refer to the (Picture 2) 

 

 PICTURE 2

.

 

 

Содержание Excelair EOHA30GR

Страница 1: ...odel EOHA30GR IMPORTANT Please carefully read the Operation Manual before using the infrared heater This Operation Manual contains the important information on your safety as well as some recommendations on proper use of the appliance and its maintenance ...

Страница 2: ...NTENTS PAGE 3 SAFETY INSTRUCTIONS PAGE 3 5 HEATER COMPONENTS PAGE 6 TECHNICAL SPECIFICATIONS PAGE 7 OPERATING THE HEATER PAGE 7 10 INSTALLATION CEILING OR WALL MOUNT PAGE 11 16 TROUBLESHOOTING PAGE 17 WARRANTY INFORMATION PAGE 18 ...

Страница 3: ... installed socket outlet with earth contact The heater should be connected to the electric mains equipped with an automatic circuit breaker The unit must be handled with care and avoid vibration or hitting WARNING FIRE RISK EXISTS IF THE HEATER IS COVERED BY OR POSITIONED CLOSE TO CURTAINS OR OTHER COMBUSTIBLE MATERIALS Do not use the appliance areas where gasoline paint or other flammable liquids...

Страница 4: ... are cold with a damp soft cloth Always remove plug from the mains supply before cleaning The heater must be installed at least 2 2 m above the floor The heater must not be located immediately below a socket outlet The heater must not be located in front of a socket outlet They should be located outside the physical footprint of the units to minimize heat build up behind the heater The installatio...

Страница 5: ...he ceiling coating and ceiling material should be at least 80 C WARNING This heater is not equipped with a device to control the room temperature This heater is to be used in open alfresco environment or large areas with high ceilings The heater must not be within reach from the floor as severe burns may occur due to high surface temperatures Do not use this heater in small rooms or where the room...

Страница 6: ...Page 6 HEATER COMPONENETS 1 Ceramic Glass Panel 2 ON OFF main power switch 3 Power cord and plug 4 Bracket for wall or ceiling mounting 5 Remote control ...

Страница 7: ...he heating or cooling period This is normal operational noise NOTE After switching on the appliance for the first time and following extended periods on non use the appliance may expel a slight odour for a short time It will not affect the use of the heater To exclude unpleasant burnt odour it is recommended to keep the heater clean preventing accumulation of dust on it The distance between the he...

Страница 8: ...itch to the position of I refer to picture 1 The device will sound 1beep one of the heat lamp indicators will flash picture 1 the device is in standby mode and the unit won t radiate any heat PICTURE 1 2 Point the remote control directly to the receiver press the ON button on remote the device will sound 1 beep and the unit will start to heat in high power mode 100 of the rated power and all three...

Страница 9: ... power mode 33 of the rated power refer to Picture 3 PICTURE 3 5 To change the heater from STANDY MODE to MEDIUM HEAT point the remote directly to the heater and press the MED button on the remote The device will sound 1 beep two of the heat lamp indicators will turn red and the heater will start to heat in medium power mode 66 of the rated power refer to Picture 4 PICTURE 4 6 To change the heater...

Страница 10: ...HOURS point the remote control directly to the receiver and press the 2hr button the 2nd of the timer lamp indicators will turn green in color The device will be powered off after 2 hours returning to standby mode and the heat lamp indicator light will turn red and flash 3 To activate the AUTOMATIC SHUT OFF TIMER for 3 HOURS point the remote control directly to the receiver and press the 1hr 2hr b...

Страница 11: ...le angle mounting brackets The adjustable angle enables the heater to be installed on vertical horizontal and inclined surfaces The ideal mounting position is directly above the area to be heated with a longitudinal orientation and facing vertically downwards Warning The heater must never be installed in the upwards or inwards facing position the heating surface must always be positioned to direct...

Страница 12: ...Page 12 Clearances Minimum clearances when mounting the heater parallel with a ceiling Minimum clearances when mounting the heater at an angle to the ceiling ...

Страница 13: ...Page 13 WALL MOUNTING FOR EOHA30GR Minimum clearances when mounting the heater on A VERTICAL WALL ...

Страница 14: ...cking paper sheet from the end of heater 3 Take out one pair of mounting Brackets These adjustable brackets allow the product to be mounted to a wall or ceiling and come with preset angle options of parallel 15 30 45 and height 170mm 4 For the correct installation process use the diagram above for requirements Select the heater location on the ceiling or wall by locating the stud or structural bea...

Страница 15: ...to desired angle and fasten brackets by spanner For wall mounted installation the available mount angles are restricted to 15 30 and 45 only For ceiling mounted installation the available mount angles are restricted to 0 15 and 30 only 7 Hang the heater on the brackets and firmly secure in place with the mounting bracket locking plates by tightening bolts labelled A ...

Страница 16: ... make sure that specifications of the electric mains at the connection point meet the single phase 230 240V 50Hz voltage The electric mains should be equipped with an automatic circuit breaker with rated current not less than 16A The heater must not be located immediately below a power point Power point should not be located at the back of the heater The power point needs to be located outside the...

Страница 17: ...en turned on after periods of no use Build up of debris and dust on the heater Switch the heater off and allow it to cool down and then clean Clinking noises when heater is turned on and after being turned off This is expansion and contraction noises of the heaters metal components and is normal Poor heating performance Exposure to extreme ambient conditions such as high winds excessively cold tem...

Страница 18: ...r element Turn off the heater and return to place of purchase if in warranty Will not heat No operation indicator Check that power is connected and switched on if still faulty Turn off the heater and return to place of purchase if in warranty WARRANTY This appliance is guaranteed for a period of 24 months If during this period the appliance fails to work due to parts or manufacture fault please re...