NOTE:
ü
Depending on material and design of wall structural elements, the heater must
be secured with the correct fasteners. The weight of the heater is up to 5.3Kg,
the installation location must be able to hold 5 times the weight of the heater.
CONNECTION TO ELECTRIC MAINS
•
The heater is designed for connection to the single-phase 230-240V~ 50HZ
electric mains equipped with a earth.
•
Before connection, make sure that specifications of the electric mains at the
connection point meet the single-phase 230-240V~ 50Hz voltage.
•
The electric mains should be equipped with an automatic circuit breaker with
rated current not less than 16A.
•
The heater must not be located immediately below a power point. Power point
should not be located at the back of the heater. The power point needs to be
located outside the physical footprint of the heater to minimize heat build-up
behind the heater.
If the heater is to be mounted on an incline (eg. Vaulted
ceiling), ensure the power point located at that lowest point of the heater.