installer Programmable Features (cont’d)
Feature #8 - PinK/WhiTe (ign #2)Wire Function
ignition
(press “
lock
” button to program)
- DeFaulT
accessory
(press “
unlock
” button to program)
Starter
(press “
trunk
” button to program)
This feature changes the operation of the unit’s large PINK/WHITE output wire.
This feature
should only be programmed by the installer
Feature #7 - Starter Cranking Time
0.75 Second
(press “
lock
” button to program)
- DeFaulT
1.00 Second
(press “
unlock
” button to program)
1.5 Seconds
(press “
trunk
” button to program)
2.25 Seconds
(press “
start
” button to program)
This feature determines the crank time of the 1st start attempt when in “Tachless” mode. If the
engine doesn’t start on the first attempt, it will retry up to 3 more times extending the crank time by
an additional 02 second with each attempt
Feature #9 - arm, Disarm or additional Channels
arm / Disarm
(press “
lock
” button to program)
- DeFaulT
arm / Channel 5
(press “
unlock
” button to program)
Channel 4 / Disarm
(press “
trunk
” button to program)
Channel 4 / Channel 5
(press “
start
” button to program)
The system has outputs designed for arming and/or disarming a factory-equipped security system.
These wires may be used instead to provide further system outputs, which are remotely operated
by the controller or transmitter These outputs are in addition to the 2nd channel and 3rd channel
outputs. As shown in the programming assignment, the arm, disarm, channel 4 and channel 5 are
programmable as various combinations. For example, if the disarm output is needed, but not the
arm output, then channel 4 may be made available for use.
Feature #11 Remote Start lock Control
Off
(press “
lock
” button to program)
- DeFaulT
lock after Start
(press “
unlock
” button to program)
unlock before start
(press “
trunk
” button to program)
unlock lock after Start
(press “
start
” button to program)
This feature allows for OEM alarm/lock control in relation to remote start operations thus eliminat
-
ing extra wiring
Feature #10 gasoline Or Diesel engine
gasoline
(press “
lock
” button to program)
- DeFaulT
Diesel 15 Sec. Delay
(press “
unlock
” button to program)
Diesel 20 Sec. Delay
(press “
trunk
” button to program)
Diesel 30 Sec. Delay
(press “
start
” button to program)
This feature changes the system’s timing of the ignition and starter output sequence for gas or
diesel engines Gasoline
: the starter output will occur 3 seconds after the ignitions turn on. When
in “Tachless” mode, the engine running status is determined 10 seconds after starting.
Diesel:
the starter output will occur 15, 20, or 30 seconds after the ignitions turn on (allows for glow plug
warming). When in “Tachless” mode, the engine running status will be determined 40 seconds
after cranking.
Содержание AL-185X-EDPB