background image

 
 
B. Tools Recommended for Reverse Osmosis 
Installation 

 

 

 

 
C. Site Selection for Major System Reverse 
Osmosis Components 

The following tools will cover most of the 
Reverse Osmosis installation sites 
encountered: 

 

The Reverse Osmosis  System was designed to fit 
under a sink, however, because of space limitations 
or other reasons, the Reverse Osmosis system's 
flexible design allows for other locations. When 
determining the location of your Reverse Osmosis 
system remember that access to a cold water tap 
line, the household drain, and ease of Reverse 
Osmosis filter replacement are important 
considerations. 

All Reverse Osmosis components and tubing 
should be located in an area not exposed to 
freezing temperatures. If winter temperatures are 
sever, the area should be above the minimum 
temperature listed in Table B, page 2 for proper 
performance. Do not expose Reverse Osmosis 
system or tubing to direct sunlight. 

1.  3/8" variable speed electric drill. 

 

2.  Extension work light with outlet. 

 

3.  Safety glasses. 

 

4.  5/8" Drill Bit and 1/8" and  ½"metal drill bits 

for pilot hole. 

 

6.  Center punch and hammer. 

 

7.  Wood bits. 

 

8.  Concrete drill bits. 

 

9.  Assorted wood and metal drill bits including 

7/32" metal drill bit. 

 

1.  Reverse Osmosis Drinking Faucet

 – The 

Reverse Osmosis faucet should be placed near 
the sink where drinking water is normally 
obtained. Convenience of use (filling of water 
pitchers and glasses), and an open area 
beneath the Reverse Osmosis faucet under the 
sink for attaching product and Reverse Osmosis 
drain tubing are considerations. A 2" diameter 
flat surface is required above and below the 
Reverse Osmosis installation site.  

10. Phillips head and flat blade screwdrivers. 

 

11. ½", 9/16" and 5/8" open end wrenches. 

 

12. 10" Crescent wrench with jaws taped to 

hold faucet. 

 

13. Basin wrench or 10" pipe wrench. 

 

14. Teflon tape. 

 

15. Wide masking tape or duct tape. 

 

16. Plastic tubing cutter. 

 

17. Extra plastic tubing. 

 

2.  Reverse Osmosis Holding Tank

 – The 

Reverse Osmosis Holding Tank may be placed 
where it is convenient within 10 feet of the 
Reverse Osmosis faucet; under the sink, in an 
adjacent cabinet are the best choices or in a 
basement within 20 feet of the Reverse Osmosis 
faucet. If a longer run of Reverse Osmosis 
tubing is required, a transfer delivery pump may 
be required extra to boost line pressure. 

18. Low range air pressure gauge. 

 

19. Small bottle of liquid chlorine bleach. 

 

20. Paper towels, wisk broom and assorted 

clean up materials. 

 

 

 

 

 

 

 

3.  Reverse Osmosis Manifold Assembly

 – The 

Reverse Osmosis  manifold can be installed on 
either the right or left side of the under-sink area 
or a cabinet. The right side is recommended 
because all the Reverse Osmosis tubing will be 
to the back of the cabinet and out of the way. 
Reverse Osmosis Installation in the basement is 
also an option; one location is near the 
laundry/utility sink where cold potable water and 
rain access are handy. The mounting location 
should allow adequate clearance and 
accessibility for Reverse Osmosis cartridge 
changes. 

 

Содержание EWR 5075

Страница 1: ...Model EWR 5075 INSTALLATION OPERATION SERVICE MANUAL Barrie Ontario Canada www excaliburwater com REVERSE OSMOSIS DRINKING WATER SYSTEMS...

Страница 2: ...se Osmosis Water Quality 10 REVERSE OSMOSIS TROUBLESHOOTING GUIDE 11 12 CAUTION The Centers for Disease Control and Prevention CDC and the Environmental Protection Agency EPA have issued guidance to p...

Страница 3: ...f these pores typically 800 1200 square meters per gram of carbon gives the Reverse Osmosis carbon very good adsorption sites for substances that contribute to tastes and odours The Reverse Osmosis ca...

Страница 4: ...Carbon Post Filter 2 Filter Housings with O Rings 12 Other items necessary for Reverse Osmosis installation may include wood screws or machine screws and nuts for mounting the manifold or concrete anc...

Страница 5: ...3 BALL...

Страница 6: ...nd an open area beneath the Reverse Osmosis faucet under the sink for attaching product and Reverse Osmosis drain tubing are considerations A 2 diameter flat surface is required above and below the Re...

Страница 7: ...component position 2c Drilling a counter top NOTE The counter top must be less than 2 thick Treat ceramic tiles as porcelain until the tile is penetrated then use the carbide tipped metal cutter Form...

Страница 8: ...Reverse Osmosis to a hot water feed line Water over 100 F may cause permanent damage to the Reverse Osmosis Membrane Refer to Fig 3 page 8 1 Shut off the water supply and drain the line from the Reve...

Страница 9: ...er is flowing to drain Refer to Fig 4 below To connect the Drain Tubing install the Compression Nut and the Brass Insert Insert the tubing into the Drain Clamp and tighten the Compression Nut Choose t...

Страница 10: ...y fine black powder from the In Line Activated Carbon Post Filter to be rinsed out This is normal for the first tank of water or after the In line filter is changed 1 Check the Reverse Osmosis tank pr...

Страница 11: ...ve the wrapping and install the Reverse Osmosis Activated Carbon Pre filter Firmly tighten the Reverse Osmosis Housing hand tight only Disconnect the Reverse Osmosis tubing that runs from the Reverse...

Страница 12: ...m or Milligrams per Liter mg l of Total Dissolved Solids TDS Although technically they are not exactly equal in most discussions ppm mg l Reverse Osmosis Membranes are rated by the amount of dissolved...

Страница 13: ...mosis Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air pre charge in the Reverse Osmosis Holding Tank is too low Empty water from Reverse Osmosis Holding Tank...

Страница 14: ...Correct plumbing Dissolved gassed in the Reverse Osmosis Feed Water Pre treat Reverse Osmosis Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Reverse Osmosis P...

Страница 15: ...e above warranties are effective provided the Reverse Osmosis System is operated at water pressures not exceeding 125psi and at water temperatures not exceeding 120 F also provided that the RO system...