Excalibur Water Systems EWR 5075 Скачать руководство пользователя страница 11

REVERSE OSMOSIS OPERATION & 
MAINTENANCE 

 

1.  Close the Reverse Osmosis Feed Water Ball 

Valve by turning fully clockwise and open the 
Reverse Osmosis  Dispensing Faucet by 
lifting the handle. Allow the Reverse 
Osmosis Holding Tank to empty. 

2.  Loosen and remove the Reverse Osmosis 

Sediment Pre-filter and the Activated Carbon 
Pre-filter Housings. Wash the inside of the 
Reverse Osmosis  Housings using a mild 
detergent and a soft cloth. Do not use 
abrasive cleaners or pads. Thoroughly rinse 
all soap from the Reverse Osmosis 
Housings before reassembly. 

3.  To sanitize the Reverse Osmosis system 

and replace the Reverse Osmosis filters: 

NOTE:

 The Reverse Osmosis system should 

be sanitized before installing the Reverse 
Osmosis  Activated Carbon Pre-filter. 

  Use a good quality unscented liquid 

chlorine household bleach. 

  Add one capful Reverse Osmosis 

Sediment Pre-filter Housing and install the 
Reverse  Osmosis Housing O-ring for 
proper position in its groove, engage and 
firmly tighten the Housing hand tight only. 

  Add one capful of bleach to the  

Reverse Osmosis Activated Carbon Pre-
filter Housing. Install the Reverse Osmosis 
Housing without the Reverse Osmosis 
Activated Carbon Pre-filter. 

  The Reverse Osmosis Dispensing Faucet 

should be open, slowly open the Reverse 
Osmosis Feed Water Ball  Valve. 

  As soon as the water begins to drip out of 

the Dispensing Faucet, close the Faucet. 

  Let the Reverse Osmosis system stand for 

15 minutes. 

  At the end of 15 minutes, in the following 

order, close the Reverse Osmosis Feed 
Water Ball  Valve, close the Reverse 
Osmosis Holding Tank Valve and open the 
Dispensing Faucet to release the pressure. 

  Remove the Reverse Osmosis Activated 

Carbon Pre-filter Housing and empty. 
Remove the wrapping and install the 
Reverse Osmosis  Activated Carbon Pre-
filter. Firmly tighten the Reverse Osmosis 
Housing hand tight only.  

  Disconnect the Reverse Osmosis tubing 

that runs from the Reverse Osmosis 
Holding Tank to the Tee (see Fig. 1, page 
3). Put 50 drops of bleach (this is ½ tsp. or  

A.  Reverse Osmosis Normal Operation 

 

1. Reverse Osmosis systems produce 

drinking water at relatively slow rates. 
Normal operation is to let the Reverse 
Osmosis Holding Tank fill with water and 
then draw water as is needed. When the 
pressure in the Reverse Osmosis Holding 
Tank falls to a given pressure (as the water 
is being used) the Automatic Shut-Off 
Valve (ASO Valve) will start water 
production and the Reverse Osmosis 
system will refill the Reverse Osmosis 
Holding Tank. When the Reverse Osmosis 
Holding Tank is full and no water is being 
used, the ASO Valve will automatically shut 
off the feed water to conserve water. The 
more water that is used (up to the capacity 
of the system) the better the Reverse 
Osmosis system will function.  

After periods of non-use, such as a week 
of vacation, it is better to empty the 
Reverse Osmosis Holding Tank and allow 
the Reverse Osmosis system to produce 
fresh water for use. If the Reverse 
Osmosis system is not used for 3-4 weeks 
or longer, it is a good idea to re-sanitize the 
Reverse Osmosis system and to change 
the Reverse Osmosis pre-filter and post 
filters. 

 
 

B.  Reverse Osmosis Changing Filters 

 

THIS REVERSE OSMOSIS  SYSTEM 
CONTAINS REVERSE OSMOSIS FILTERS 
WHICH MUST BE REPLACED AT 
REGULAR INTERVALS TO MAINTAIN 
PROPER PERFORMANCE. USE ONLY 
FACTORY APPROVED FILTERS. 

The recommended interval for changing the 
Reverse Osmosis  filters (not the Reverse 
Osmosis  Membrane) is every six (6) months. 
Typical T.F.C. Reverse Osmosis Membrane 
life expectancy is Five to ten years with 
Water Softener prior to Reverse Osmosis 
system. Local conditions may dictate more 
frequent changes. 

 

 

 

Содержание EWR 5075

Страница 1: ...Model EWR 5075 INSTALLATION OPERATION SERVICE MANUAL Barrie Ontario Canada www excaliburwater com REVERSE OSMOSIS DRINKING WATER SYSTEMS...

Страница 2: ...se Osmosis Water Quality 10 REVERSE OSMOSIS TROUBLESHOOTING GUIDE 11 12 CAUTION The Centers for Disease Control and Prevention CDC and the Environmental Protection Agency EPA have issued guidance to p...

Страница 3: ...f these pores typically 800 1200 square meters per gram of carbon gives the Reverse Osmosis carbon very good adsorption sites for substances that contribute to tastes and odours The Reverse Osmosis ca...

Страница 4: ...Carbon Post Filter 2 Filter Housings with O Rings 12 Other items necessary for Reverse Osmosis installation may include wood screws or machine screws and nuts for mounting the manifold or concrete anc...

Страница 5: ...3 BALL...

Страница 6: ...nd an open area beneath the Reverse Osmosis faucet under the sink for attaching product and Reverse Osmosis drain tubing are considerations A 2 diameter flat surface is required above and below the Re...

Страница 7: ...component position 2c Drilling a counter top NOTE The counter top must be less than 2 thick Treat ceramic tiles as porcelain until the tile is penetrated then use the carbide tipped metal cutter Form...

Страница 8: ...Reverse Osmosis to a hot water feed line Water over 100 F may cause permanent damage to the Reverse Osmosis Membrane Refer to Fig 3 page 8 1 Shut off the water supply and drain the line from the Reve...

Страница 9: ...er is flowing to drain Refer to Fig 4 below To connect the Drain Tubing install the Compression Nut and the Brass Insert Insert the tubing into the Drain Clamp and tighten the Compression Nut Choose t...

Страница 10: ...y fine black powder from the In Line Activated Carbon Post Filter to be rinsed out This is normal for the first tank of water or after the In line filter is changed 1 Check the Reverse Osmosis tank pr...

Страница 11: ...ve the wrapping and install the Reverse Osmosis Activated Carbon Pre filter Firmly tighten the Reverse Osmosis Housing hand tight only Disconnect the Reverse Osmosis tubing that runs from the Reverse...

Страница 12: ...m or Milligrams per Liter mg l of Total Dissolved Solids TDS Although technically they are not exactly equal in most discussions ppm mg l Reverse Osmosis Membranes are rated by the amount of dissolved...

Страница 13: ...mosis Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air pre charge in the Reverse Osmosis Holding Tank is too low Empty water from Reverse Osmosis Holding Tank...

Страница 14: ...Correct plumbing Dissolved gassed in the Reverse Osmosis Feed Water Pre treat Reverse Osmosis Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Reverse Osmosis P...

Страница 15: ...e above warranties are effective provided the Reverse Osmosis System is operated at water pressures not exceeding 125psi and at water temperatures not exceeding 120 F also provided that the RO system...

Отзывы: