Excalibur Water Systems EWR 5075 Скачать руководство пользователя страница 10

D.  Position the Reverse Osmosis Holding 

Tank & Make the Final Hose Connections 

 

  Slowly open the Reverse Osmosis Feed 

Water Saddle Valve (turning counter 
clockwise). 

  As soon as the water begins to come out of 

the Reverse Osmosis Dispensing Faucet, 
close the Faucet. 

  Let stand for 15 minutes. 

NOTE: 

During this time, check the Reverse 

Osmosis system carefully for leaks. 

  At the end of 15 minutes, CLOSE the 

Reverse Osmosis Feed Water Ball Valve 
and open the Reverse Osmosis Dispensing 
Faucet. 

  Allow the Reverse Osmosis Holding Tank to 

completely drain. Then remove the Reverse 
Osmosis  Activated Carbon Pre-filter 
Housing, empty, and install the Reverse 
Osmosis activated Carbon Pre-filter. Firmly 
tighten the Reverse Osmosis Housing hand 
tight only. 

2.  Installing the Reverse Osmosis 

Membrane: 

  Remove the Reverse Osmosis  Membrane 

Housing, (the closest of the three to In/Out 
ports), and empty. 

  Insert the Reverse Osmosis Membrane into 

the Reverse Osmosis Membrane Housing. 
(The O-rings should be up toward the 
Reverse Osmosis Membrane Housing cap.) 
Check the Reverse Osmosis Housing O-ring 
for proper position in its groove, engage and 
firmly tighten the Reverse Osmosis Housing 
hand tight only. 

3.  Rinsing the Reverse Osmosis system: 

  Slowly open the Reverse Osmosis Feed 

Water Saddle Valve fully counter clockwise. 

 The Reverse Osmosis Holding Tank Valve 

should be open. The Reverse Osmosis  
System is now making water. 

  Do not use the first three full Reverse 

Osmosis tanks of water. 

CAUTION:

 The Reverse Osmosis 

Membrane is shipped with a preservative in 
it (0.5% sodium metabisulfite). This will be 
rinsed out with the first water produced. 
Allow the Holding Tank to fill (overnight) and 
discard the first three full tanks of production.  

When the Faucet is first opened, expect air 
and carbon fines (very fine black powder) 
from the In-Line Activated Carbon Post Filter 
to be rinsed out. This is normal for the first 
tank of water or after the In-line filter is 
changed. 

1. Check the Reverse Osmosis tank pre-

charge pressure. Make sure it is between 5 
to 7 psig.  

 

2. Pull the cap/plug off the top of the Reverse 

Osmosis tank where the Reverse Osmosis 
Tank Shut-Off should go. (Refer to Fig. 1, 
page 2) 

 

3. Wrap Teflon tape three times around the 

¼" male outlet thread. Wrap in the direction 
of the threads. The tape will act as a thread 
sealant. Screw on the Reverse Osmosis 
Holding Tank Shut-Off Valve. 

 

4. Locate the 3/8" Reverse Osmosis Tubing. 

Firmly press one end into the Reverse 
Osmosis Holding Tank Shut-Off Valve and 
the other end into the tee. (Refer to Fig. 1, 
page 2.) The fittings will grab the Reverse 
Osmosis tubing and seal it in place. Make 
sure the Reverse Osmosis tubing is 
pressed all the way in to create a pressure 
tight connection. 

 

E.  Reverse Osmosis Start Up 

 

At time of start up and each time the Reverse 
Osmosis filters are changed the Reverse 
Osmosis system should be sanitized. 

 

1.  Sanitizing the Reverse Osmosis system 

and installing the Reverse Osmosis 
Sediment Pre-filter. Use a drip pan to aid 
clean-up. 

NOTE:

 The Reverse Osmosis system should 

be sanitized BEFORE installing the Reverse 
Osmosis Activated Carbon Pre-filter and the 
Reverse Osmosis  Membrane. 

  Use a good quality unscented liquid 

chlorine household bleach. 

  Open the Reverse Osmosis Dispensing 

Faucet by lifting the black handle and open 
the Reverse Osmosis Holding Tank Shut-
Off Valve (the handle should be parallel 
with the valve body). 

  Remove the Reverse Osmosis Housing on 

the side of the manifold labeled 
"SEDIMENT". Pour one capful of bleach 
(this is approximately 2 tsp. or 10 ml) into 
one of the white Housings.. Engage and 
firmly tighten the Reverse Osmosis 
Housing hand tight only. 

  Remove all Reverse Osmosis Housings 

add one capful of bleach in each. Engage 
and firmly tighten the Housings hand tight 
only. 

 

 

Содержание EWR 5075

Страница 1: ...Model EWR 5075 INSTALLATION OPERATION SERVICE MANUAL Barrie Ontario Canada www excaliburwater com REVERSE OSMOSIS DRINKING WATER SYSTEMS...

Страница 2: ...se Osmosis Water Quality 10 REVERSE OSMOSIS TROUBLESHOOTING GUIDE 11 12 CAUTION The Centers for Disease Control and Prevention CDC and the Environmental Protection Agency EPA have issued guidance to p...

Страница 3: ...f these pores typically 800 1200 square meters per gram of carbon gives the Reverse Osmosis carbon very good adsorption sites for substances that contribute to tastes and odours The Reverse Osmosis ca...

Страница 4: ...Carbon Post Filter 2 Filter Housings with O Rings 12 Other items necessary for Reverse Osmosis installation may include wood screws or machine screws and nuts for mounting the manifold or concrete anc...

Страница 5: ...3 BALL...

Страница 6: ...nd an open area beneath the Reverse Osmosis faucet under the sink for attaching product and Reverse Osmosis drain tubing are considerations A 2 diameter flat surface is required above and below the Re...

Страница 7: ...component position 2c Drilling a counter top NOTE The counter top must be less than 2 thick Treat ceramic tiles as porcelain until the tile is penetrated then use the carbide tipped metal cutter Form...

Страница 8: ...Reverse Osmosis to a hot water feed line Water over 100 F may cause permanent damage to the Reverse Osmosis Membrane Refer to Fig 3 page 8 1 Shut off the water supply and drain the line from the Reve...

Страница 9: ...er is flowing to drain Refer to Fig 4 below To connect the Drain Tubing install the Compression Nut and the Brass Insert Insert the tubing into the Drain Clamp and tighten the Compression Nut Choose t...

Страница 10: ...y fine black powder from the In Line Activated Carbon Post Filter to be rinsed out This is normal for the first tank of water or after the In line filter is changed 1 Check the Reverse Osmosis tank pr...

Страница 11: ...ve the wrapping and install the Reverse Osmosis Activated Carbon Pre filter Firmly tighten the Reverse Osmosis Housing hand tight only Disconnect the Reverse Osmosis tubing that runs from the Reverse...

Страница 12: ...m or Milligrams per Liter mg l of Total Dissolved Solids TDS Although technically they are not exactly equal in most discussions ppm mg l Reverse Osmosis Membranes are rated by the amount of dissolved...

Страница 13: ...mosis Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air pre charge in the Reverse Osmosis Holding Tank is too low Empty water from Reverse Osmosis Holding Tank...

Страница 14: ...Correct plumbing Dissolved gassed in the Reverse Osmosis Feed Water Pre treat Reverse Osmosis Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Reverse Osmosis P...

Страница 15: ...e above warranties are effective provided the Reverse Osmosis System is operated at water pressures not exceeding 125psi and at water temperatures not exceeding 120 F also provided that the RO system...

Отзывы: