background image

not allowing water to exit from the control valve to the 
plumbing system.  

 

 

D) SHUTOFF 

POSITION 

 

The inlet handles points to the centre of the bypass valve 
and the outlet points to the direction of flow.  The water is 
shut off to the plumbing system.  If water is available on the 
outlet side of the Water Softener/Filter, it is an indication of 
water bypass around the system.   
 

 

 
 
 

WATER SOFTENER/FILTER STARTUP INSTRUCTIONS 

 

  After Water Softener/Filter installation is completed and 

checked for leaks, rotate the bypass valve handles to the 
bypass position.  

 

Содержание CHLOROSOFT SERIES

Страница 1: ...CHLOROSOFT SERIES ELECTRONIC METERED WATER SOFTENER FILTER Installation Manual 220 Bayview Avenue Unit 18 Barrie Ontario Canada L4N 4Y8 www excaliburwater com...

Страница 2: ...ur Chlorosoft Water Softener Filter on black o rings but is not necessary Avoid any type of lubricants including silicone when installing your Chlorosoft Water Softener Filter on red or clear lip seal...

Страница 3: ...k should be on a firm level surface The plug in transformer is for dry location only Electrical use of 115 120 volt 60 Hz uninterrupted outlet Batteries are not used 1 The distance between the Chloros...

Страница 4: ...ng assemblies When assembling the Water Softener Filter installation fitting package inlet and outlet connect the fitting to the plumbing system first and attach the Water Softener Filter nut split ri...

Страница 5: ...es for air gaps and anti siphon devices 8 WATER SOFTENER FILTER BRINE TANK CONNECTION Install a 3 8 inch outside diameter polyethylene tubing from the Water Softener Filter refill elbow to the brine v...

Страница 6: ...lly used to isolate the Water Softener Filter control valve from the plumbing system water pressure in order to perform Water Softener Filter control valve repairs or maintenance The bypass valve is p...

Страница 7: ...outlet handles point to the centre of the bypass valve The bypass valve is isolated from the water pressure contained in the plumbing system Untreated water is supplied to the plumbing system C DIAGN...

Страница 8: ...ts to the direction of flow The water is shut off to the plumbing system If water is available on the outlet side of the Water Softener Filter it is an indication of water bypass around the system WAT...

Страница 9: ...slowly to expel air If water flows too rapidly there will be a loss of media out of the drain 4 When the Water Softener Filter is flowing steadily to drain without the presence of air press the Water...

Страница 10: ...uto or to a number sets the maximum number of days between regenerations If valve set to off regeneration initiation is based solely on gallons used If valve is set as a number allowable range 1 to 28...

Страница 11: ...lve set at NORMAL on 0 e Check control valve set up procedure regeneration time option a Control valve has just been serviced a Press NEXT and REGEN for 3 seconds or unplugged power source jack black...

Страница 12: ...gear or drive cap assembly c Replace drive gear or drive cap assembly and held d Defective PC board d Replace PC board 8 Control valve does not a By pass valve in bypass position a Put bypass valve i...