4. PROCESSING CONTROLS
Due to the precision and computational intensity of our proprietary calibration process, the full
phase and magnitude calibration introduces approximately 40ms of latency. The setting “full”
reflects this complete phase and magnitude calibration. For those applications such as tracking
where minimal latency is necessary, the “min latency” setting removes the phase calibration and
applies only a magnitude calibration, which reduces the total system latency to approximately
2ms.
Always make sure both loudspeakers are set to the same processing setting during
operation to avoid phase distortion between the two speakers.
5. BOUNDARY CONTROLS
Pulsar and Quasar are both factory calibrated for optimal performance in full space setups,
away from side and rear walls. If setup close to a rear wall is necessary, the boundary control
can be set to “half” to compensate, and if setup close to both a rear and side wall is necessary,
the boundary control can be set to “quarter” to compensate.
6. FIRMWARE INPUT
The USB input labeled “firmware” is for internal use only in calibration and servicing. The 3D
printed cap that comes attached to it is solely to protect the switches during shipping and
transport.
This input cannot be used for USB audio.