SECTION 4: CONNECTIONS AND CONTROLS
1. IEC INLET
Ganymede uses auto-switching power supplies, and will automatically adapt to 110/220v power
operation. Should you ever need to replace the provided 6 foot IEC cable, please ensure you
use a properly grounded, 3-prong IEC of at least 16AWG.
Never use a 2-conductor power
cable or leave the ground disconnected.
2. POWER INDICATOR
A white LED indicator will illuminate when the loudspeaker is switched on and operational.
Please allow 25-30 seconds after power on for the DSP to boot up before sending audio signals
to the loudspeaker.
Additionally, ALWAYS allow 45 seconds for complete DSP shutdown
after turning the loudspeaker off before turning it back on again. Failure to do so may
result in memory and startup errors.
11