ES2030 CV
Initiating regeneration manually / Special functions
9
Initiating regeneration manually
A regeneration cycle can be initiated manually
at any time pressing the ‘Start’ key with the
symbol . Regeneration of the filter in service
commences after six seconds.
- In the case of systems operating alternately,
the standby filter is put into service.
- If ‘delayed regeneration’ was selected at
step 6.1 of the programming, the time
function is activated and the time at which
the delayed regeneration will be initiated
automatically is displayed at the bottom left
of the LCD display.
- No regeneration is yet initiated.
- If the time function for ‘delayed regeneration’
has already been activated (and the time
regeneration will be initiated is already
displayed at the bottom left of the LCD
display), regeneration will be initiated after
four seconds regardless of the time shown.
- The filter’s flow counter is reset to full
capacity after regeneration.
- If initiation at intervals was selected at step
7.1 during the input of basic values, the hour
interval meter is set to its preset interval.
- If a minimum regeneration interval was
selected at step 8.1 during the input of basic
values, the timer for the regeneration interval
is reset.
Special functions
These functions should only be used by a professional water treatment specialist, as their improper
use may lead to malfunctions.
Filter change over without program
initiation
Simultaneously press the function keys with
the symbols and . Change over of the
filters will take place after 4 seconds on two
filter systems.
NOTE: Separate flow counters are used for
each filter. Where an almost saturated filter is
switched into the standby position, it may
happen that regeneration becomes necessary
shortly after it has been brought into service,
and this may be at a time when the other filter
is still regenerating. In this event, the fault
warning ‘capacity exceeded’ appears.
Immediate Stop
Simultaneously press the function keys with
the symbols and .
Any regeneration program running will stop
after 4 seconds and the system will be
switched into service position.
NOTE: Multi stage valves which have no
connection to return them automatically to the
service setting will remain at a regeneration
setting and are no longer synchronized with
the control panel.
Regeneration of standby filter
Simultaneously press the function keys with
the symbols and .
The regeneration of the standby filter will begin
after 4 seconds on two filter systems
NOTE: this only applies for alternate filter
service (program step 5.3 = YES).
OUT
1
OUT
1
OUT
1
OUT
1
OUT
1
OUT
1