Technical data
Taurus 401 Basic FKW
64
099-005230-EW501
02.04.2014
8
Technical data
NOTE
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Taurus 401 Basic FKW
Setting range for welding current/voltage:
MMA
5 A/20.2 V to 400 A/36.0 V
MIG/MAG
5 A/14.3 V to 400 A/34.0 V
Duty cycle at 40 °C
100%
400 A
Load alternation
10 min. (60% DC
6 min. welding, 4 min. pause)
Open circuit voltage
79 V
Mains voltage (tolerances)
3 x 400 V (-25% to +20%)
Frequency
50/60 Hz
Mains fuse (safety fuse, slow-blow)
3 x 32 A
Mains connection lead
H07RN-F4G6
Maximum connected load
MIG/MAG
17.5 kVA
MMA
18.5 kVA
Recommended generator rating
25 kVA
cos
0.99
Insulation class/protection classification
H/IP 23
Ambient temperature*
-25 °C to +40 °C
Machine/torch cooling
Fan/gas or water
Cooling capacity at 1 l/min
1500 W
Max. flow rate
5 l/min
Max. coolant outlet pressure
3.5 bar
Max. tank capacity
12 l
Welding lead
70 mm²
Dimensions L x W x H in mm
1100 x 455 x 950
Weight
120 kg
Wire feed speed
0.5 m/min to 24 m/min
Standard roller installation
1.0 mm + 1.2 mm (for steel wire)
Drive type
4-roller (37 mm)
Welding torch connection
Euro torch connector
EMC class
A
Constructed to standards
IEC 60974-1, -2, -5, -10 / /
NOTE
*
Ambient temperature depends on coolant!
Observe the coolant temperature range for the welding torch cooling!
Содержание Taurus 401 Basic FKW
Страница 18: ...Machine description quick overview Rear view 18 099 005230 EW501 02 04 2014 4 2 Rear view Figure 4 2...
Страница 20: ...Machine description quick overview Inside view 20 099 005230 EW501 02 04 2014 4 3 Inside view Figure 4 3...
Страница 70: ...Appendix B Overview of EWM branches 70 099 005230 EW501 02 04 2014 12 Appendix B 12 1 Overview of EWM branches...