Maintenance, care and disposal
General
099-005219-EW501
10.06.2013
35
6
Maintenance, care and disposal
DANGER
Risk of injury from electric shock!
Cleaning machines that are not disconnected from the mains can lead to serious
injuries!
•
Disconnect the machine completely from the mains.
•
Remove the mains plug!
•
Wait for 4 minutes until the capacitors have discharged!
6.1
General
When used in the specified environmental conditions and under normal operating conditions, this
machine is largely maintenance-free and requires a minimum of care.
There are some points, which should be observed, to guarantee fault-free operation of your welding
machine. Among these are regular cleaning and checking as described below, depending on the pollution
level of the environment and the length of time the unit is in use.
6.2
Maintenance work, intervals
CAUTION
Electric current!
Repairs may only be carried out by authorised specialist staff!
•
Do not remove the torch from the hose package!
•
Never clamp the torch body in a vice or similar, as this can cause the torch to be irreparably
destroyed!
•
If damage occurs to the torch or to the hose package which cannot be corrected as part of
the maintenance work, the entire torch must be returned to the manufacturer
6.2.1
Daily maintenance tasks
•
Check that all connections and wearing parts are hand-tight and tighten if necessary.
•
Check that all screw and plug connections and replaceable parts are secured correctly, tighten if
necessary.
•
Remove any spatter.
•
Clean the wire feed rollers on a regular basis (depending on the degree of soiling).
6.2.1.1 Visual inspection
•
Check hose package and power connections for exterior damage and replace or have repaired by
specialist staff as necessary!
•
Mains supply lead and its strain relief
•
Gas tubes and their switching equipment (solenoid valve)
•
Other, general condition
6.2.1.2 Functional test
•
Check correct mounting of the wire spool.
•
Welding current cables (check that they are fitted correctly and secured)
•
Gas cylinder securing elements
•
Operating, message, safety and adjustment devices (Functional test)
Содержание Taurus 355 Synergic S TDM
Страница 18: ...Machine description quick overview Rear view 18 099 005219 EW501 10 06 2013 4 2 Rear view Figure 4 2 ...
Страница 49: ...Appendix A JOB List 099 005219 EW501 10 06 2013 49 10 Appendix A 10 1 JOB List Figure 10 1 ...
Страница 50: ...Appendix B Overview of EWM branches 50 099 005219 EW501 10 06 2013 11 Appendix B 11 1 Overview of EWM branches ...