Design and function
Special parameters (advanced settings)
099-005407-EW501
8.2.2022
77
Display
Setting/selection
Correction operation, threshold value setting
0 = --------correction operation switched off (Ex works)
1 = --------correction operation on
"Main program (PA)" flashing
Program switching with standard welding torch
0 =
No program switching (factory setting)
1 = --------Special latched
2 = --------Special latched (n-cycle active)
3 = --------Special latched (n-cycle sequence from any program)
Lat. and sp. lat. tapping start
0 = --------no latched tapping start (Ex works)
1 = --------latched tapping start possible
One or two-wire feed operation
0 = --------single operation (Ex works)
1 = --------dual operation, this unit is the "master"
2 = --------dual operation, this unit is the "slave"
Special latched tapping time
0 = tapping function switched off
1 = 300ms (Ex works)
2 = 600ms
JOB list changeover
0 = --------task-oriented JOB list
1 = --------actual JOB list (Ex works)
2 = --------actual JOB list, JOB changeover activated via accessories
Lower limit remote JOB switching
JOB range of the function torches (PM 2U/D, PM RD2)
Lower limit: 129 (ex works)
Upper limit remote JOB switching
JOBarea of the function torch (PM 2U/D, PM RD2)
Upper limit: 169 (ex works)
HOLD function
0 = --------HOLD values are not displayed
1 = --------HOLD values are displayed (Ex works)
Block JOB mode
0 = --------Block JOB mode not enabled (Ex works)
1 = --------Block JOB mode enabled
Program selection with standard torch trigger
0 = --------no program selection (Ex works)
1 = --------program selection possible
Switching the operating mode and welding type using the wire feed control
0 = --------Switching the operating mode and welding type using the wire feed control and
program 0 (factory setting).
1 = --------Switching the operating mode and welding type using the wire feed control and
programs 0-15.
Mean value display for superPuls
0 = --------Function switched off.
1 = --------Function switched on (ex factory).
Predefined pulse arc welding process in the PA program
0 = --------Predefined pulse arc welding process in the PA program is disabled.
1 = --------If the superPuls and welding process switching functions are available and acti-
vated, the pulse arc welding process is always executed in the main program
PA (ex factory).