Design and function
Power-saving mode (Standby)
74
099-005407-EW501
8.2.2022
5.8 Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button
> see 4.3 chapter
for a pro-
longed time or by setting a parameter in the machine configuration menu (time-controlled power-saving
mode
)
> see 5.12 chapter
.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. turning a rotary knob) deactivates power-saving mode and the ma-
chine is ready for welding again.
5.9 Interfaces for automation
WARNING
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
• Appoint only skilled persons for repair work (trained service personnel)!
Unsuitable control cables or incorrect input/output signal assignment can cause damage to the
machine. Use shielded control cables only.
5.9.1 Remote control connection socket, 19-pole
Figure 5-68
Pin
Signal form Short description
A
Output
Connection for PE cable screen
C
Output
Reference voltage for potentiometer 10 V (max. 10 mA)
D
Input
Control voltage specification (0 V–10 V) – wire feed speed
E
Output
Reference potential (0 V)
F/S
Input
Welding power start/stop (S1)
G
Input
Control voltage specification (0 V–10 V) – arc length correction
P
Input
Activation of control voltage specification for wire feed speed (S2)
For activation, put signal to reference potential 0 V (pin E)
R
Input
Activation of control voltage specification for arc length correction (S3)
For activation, put signal to reference potential 0 V (pin E)
U/V
Output
Supply voltage push/pull welding torch