Design and function
Special parameters (advanced settings)
52
099-005425-EW501
14.07.2016
Enter
+
l
0
Exit
Figure 5-28
Display
Setting/selection
Ramp time for wire inching
0 = ------- normal inching (10s ramp time)
1 = ------- fast inching (3s ramp time) (Ex works)
Lat. and sp. lat. tapping start
0 = ------- no latched tapping start (Ex works)
1 = ------- latched tapping start possible
Support for wire feeders with voltage-sensing.
0 = ------ Function switched off
1 = ------ Function switched on (ex works)
Remote control encoding (Frc)
0 ---------- Automatic remote control detection (ex works)
2 ---------- Remote control encoding for accessory components with a single rotary knob
only
9 ---------- Remote control encoding for accessory components with a single pair of
buttons or a rocker only
1, 3
–8 --- No remote control encoding
10
–15 --- No remote control encoding