Design and function
MIG/MAG welding
099-005425-EW501
14.07.2016
33
Some wire electrodes (e.g. self-shielding cored wire) are welded using negative polarity. In this
case, the welding current lead should be connected to the "-" welding current socket, and the
workpiece lead should be connected to the "+" welding current socket. Observe the information
from the electrode manufacturer!
Figure 5-11
Item Symbol
Description
0
1
Workpiece
2
"-" welding current connection socket
• ----------- MIG/MAG welding: Workpiece connection
3
Welding torch
4
Welding torch hose package
5
19-pole connection socket (analogue)
For connecting analogue accessory components (remote control, welding torch control
lead, etc.)
6
Welding torch connection (Euro or Dinse torch connector)
Welding current, shielding gas and torch trigger integrated
7
Welding current cable, polarity selection
Welding current to central connection/torch. Permits polarity selection for MIG/MAG
welding.
• ----------- Standard applications > Connection for "+" welding current connection socket
8
Quick connect coupling (red)
coolant return
9
Quick connect coupling (blue)
coolant supply
Содержание Taurus 351 Basic FKG
Страница 5: ...Contents Notes on the use of these operating instructions 099 005425 EW501 14 07 2016 5 ...
Страница 16: ...Machine description quick overview Rear view 16 099 005425 EW501 14 07 2016 4 2 Rear view Figure 4 2 ...
Страница 50: ...Design and function MMA welding 50 099 005425 EW501 14 07 2016 5 4 7 Welding task selection Figure 5 27 ...
Страница 74: ...Appendix B Overview of EWM branches 74 099 005425 EW501 14 07 2016 12 Appendix B 12 1 Overview of EWM branches ...