Design and function
MIG/MAG welding
099-005266-EW501
07.05.2014
43
5.8.7
Further welding parameters
NOTE
Validity of the settings.
Settings for
•
Spot time,
•
Pause time and
•
Wire feed speed
apply for all JOBs.
•
Choke effect/dynamics,
•
Gas post-flow time,
•
Gas pre-flow time and
•
Wire burn-back correction
are saved separately for each JOB.
Changes are stored permanently in the JOB that is currently selected.
Resetting to factory configuration, see chapter “Resetting the controls (Reset all)”
5.8.7.1 Choke effect / dynamics
Operating
element
Action
Result
Display
n x
Selecting the parameter to be set
The LED indicates the parameter selected.
Parameter value set
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time (interval operation)
Set choke effect/dynamics.
Setting range:
40:
Arc hard and narrow, deeper
fusion penetration.
-40:
Arc soft and wide.
5.8.7.2 Gas post-flow time
Operating
element
Action
Result
Display
n x
Selecting the parameter to be set
The LED indicates the parameter selected.
Parameter value set
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time (interval operation)
Adjusting the gas post-flow time.
Setting range:
0.0 s to 20.0 s in increments of 0.1 s