Machine description – quick overview
Machine control – Operating elements
099-005266-EW501
07.05.2014
21
Item Symbol
Description
0
9
Gas test / rinse button
•
Gas test:
For setting the shielding gas quantity
•
Rinse:
For rinsing longer hose packages
See also "Shielding Gas Supply" chapter
10
Button, Select welding type
MIG/MAG standard welding
MIG/MAG pulse arc welding
11
Operating mode button
Non-latched
Latched
Spots
Interval
12
Welding parameter setting dial
For setting the welding performance, for selecting the JOB (welding task) and for
setting other welding parameters.
13
Arc length correction rotary dial
14
Runtime parameters button
For selecting the parameters to be set. Also for entering and exiting the menus for
advanced settings.
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time