Machine description
– quick overview
Machine control
– Operating elements
18
099-002032-EW501
15.10.2018
4.2
Machine control
– Operating elements
Figure 4-2
Item Symbol
Description
0
1
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 4.2.1 chapter
2
Collective interference signal light
For error messages,
> see 7 chapter
3
Excess temperature signal light
In case of excess temperature, temperature monitors de-activate the power unit, and
the excess temperature control lamp comes on. Once the machine has cooled down,
welding can continue without any further measures.
4
sec
Hotstart time signal light
5
AMP%
Hotstart current signal light
6
AMP
Main current signal light
Imin to Imax (1 A increments)
7
Welding parameter setting rotary transducer
Setting of welding current and other welding parameter and their values
8
VRD
Voltage reduction device (VRD) signal light
> see 5.5 chapter
9
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
10
“Arcforce” button (welding characteristics) according to electrode type
11
Welding procedure push-button
--------- TIG welding
-------- MMA welding
12
Switch display button
AMP ----- Welding current display
VOLT --- Welding voltage display