Design and function
Transport and installation
099-002032-EW501
15.10.2018
21
5.1.3.1 In operation
Temperature range of the ambient air:
• -25 °C to +40 °C (-13 °F to 104 °F)
Relative humidity:
• up to 50 % at 40 °C (104 °F)
• up to 90 % at 20 °C (68 °F)
5.1.3.2 Transport and storage
Storage in a closed room, temperature range of the ambient air:
• -30 °C to +70 °C (-22 °F to 158 °F)
Relative humidity
• up to 90 % at 20 °C (68 °F)
5.1.4
Adjusting the length of the carrying strap
To demonstrate adjustment, lengthening the strap is shown in the figure. To shorten, the strap's
loops must be inched in the opposite direction.
Figure 5-1
5.1.5
Notes on the installation of welding current leads
• Incorrectly installed welding current leads can cause faults in the arc (flickering).
• Lay the workpiece lead and hose package of power sources without HF igniter (MIG/MAG) for
as long and as close as possible in parallel.
• Lay the workpiece lead and hose package of power sources with HF igniter (TIG) for as long as
possible in parallel with a distance of 20 cm to avoid HF sparkover.
• Always keep a distance of at least 20 cm to leads of other power sources to avoid interferences
• Always keep leads as short as possible! For optimum welding results max. 30 m (welding lead
+ intermediate hose p torch lead).