Design and function
Transport and installation
18
099-002128-EW501
26.01.2022
5
Design and function
WARNING
Risk of injury from electrical voltage!
Contact with live parts, e.g. power connections, can be fatal!
• Observe the safety information on the first pages of the operating instructions!
• Commissioning must be carried out by persons who are specifically trained in handling
power sources!
• Connect connection or power cables while the machine is switched off!
Read and observe the documentation to all system and accessory components!
5.1 Transport and installation
WARNING
Risk of accident due to improper transport of machines that must not be lifted!
Do not lift or suspend the machine! The machine can drop and cause injuries! The
handles, straps or brackets are suitable for transport by hand only!
• The machine must not be suspended or lifted using a crane.
5.1.1 Machine cooling
Insufficient ventilation results in a reduction in performance and equipment damage.
• Observe the ambient conditions!
• Keep the cooling air inlet and outlet clear!
• Observe the minimum distance of 0.5 m from obstacles!
5.1.2 Workpiece lead, general
CAUTION
Risk of burning due to incorrect welding current connection!
If the welding current plugs (machine connections) are not locked or if the workpiece
connection is contaminated (paint, corrosion), these connections and leads can heat up
and cause burns when touched!
• Check welding current connections on a daily basis and lock by turning to the right when
necessary.
• Clean workpiece connection thoroughly and secure properly. Do not use structural parts of
the workpiece as welding current return lead!