background image

 

Maintenance, care and disposal 

Maintenance work, intervals 

 

099-002128-EW501 

26.01.2022

 

29

 

 

6.2  Maintenance work, intervals 

6.2.1  Daily maintenance tasks 

Visual inspection 
•  Mains supply lead and its strain relief 
•  Gas cylinder securing elements 
•  Check hose package and power connections for exterior damage and replace or have repaired by 

specialist staff as necessary! 

•  Gas tubes and their switching equipment (solenoid valve) 
•  Check that all connections and wearing parts are hand-tight and tighten if necessary. 
•  Check correct mounting of the wire spool. 
•  Wheels and their securing elements 
•  Transport elements (strap, lifting lugs, handle) 
•  Other, general condition 

 

Functional test 
•  Operating, message, safety and adjustment devices (Functional test) 
•  Welding current cables (check that they are fitted correctly and secured) 
•  Gas tubes and their switching equipment (solenoid valve) 
•  Gas cylinder securing elements 
•  Check correct mounting of the wire spool. 
•  Check that all screw and plug connections and replaceable parts are secured correctly, tighten if ne-

cessary. 

•  Remove any spatter. 
•  Clean the wire feed rollers on a regular basis (depending on the degree of soiling). 

 

6.2.2  Monthly maintenance tasks 

Visual inspection 
•  Casing damage (front, rear and side walls) 
•  Wheels and their securing elements 
•  Transport elements (strap, lifting lugs, handle) 
•  Check coolant tubes and their connections for impurities 

 

Functional test 
•  Selector switches, command devices, emergency stop devices, voltage reducing devices, message 

and control lamps 

•  Check wire guide elements (wire feed roll holder, wire feed nipple, wire guide tube) for tight fit. Recom-

mendation for replacing the wire feed roll holder (eFeed) after 2000 hours of operation, see replace-

ment parts). 

•  Check coolant tubes and their connections for impurities 
•  Check and clean the welding torch. Deposits in the torch can cause short circuits and have a negative 

impact on the welding result, ultimately causing damage to the torch. 

 

6.2.3  Annual test (inspection and testing during operation) 

A periodic test according to IEC 60974-4 "Periodic inspection and test" has to be carried out. In addition 

to the regulations on testing given here, the relevant local laws and regulations must also be observed. 
For more information refer to the "Warranty registration" brochure supplied and our information regarding 

warranty, maintenance and testing at 

www.ewm-group.com

! 

 

Содержание Pico 160

Страница 1: ...Operating instructions EN Welding machine Pico 160 Pico 160 VRD AUS 099 002128 EW501 Observe additional system documents 26 01 2022...

Страница 2: ...to the operation of this equipment is restricted solely to the function of the equipment No other form of liability regardless of type shall be accepted This exclusion of liability shall be deemed ac...

Страница 3: ...ng strap 19 5 1 5 Notes on the installation of welding current leads 20 5 1 6 Stray welding currents 21 5 1 7 Mains connection 22 5 1 7 1 Mains configuration 22 5 2 MMA welding 23 5 2 1 Connecting the...

Страница 4: ...501 26 01 2022 9 Accessories 33 9 1 Electrode holder workpiece lead 33 9 2 TIG welding torch 33 9 3 General accessories 33 9 4 Options 33 10 Service documents 34 10 1 Spare and replacement parts 34 10...

Страница 5: ...Contents Notes on using these operating instructions 099 002128 EW501 26 01 2022 5...

Страница 6: ...s and even fatal injuries Safety notes include the WARNING keyword in the heading with a general warning sym bol The hazard is also highlighted using a symbol in the page margin CAUTION Working or ope...

Страница 7: ...tch off machine Release Switch on machine Press and hold Switch Incorrect Invalid Turn Correct Valid Numerical value adjustable Input Signal light lights up in green Navigation Signal light flashes gr...

Страница 8: ...cal specialist may interconnect the sources as per standard IEC 60974 9 2010 Installa tion and use and German Accident Prevention Regulation BVG D1 formerly VBG 15 or country specific regulations Befo...

Страница 9: ...temperatures of 100 C or higher and arcing and work on live components Hearing protection against harming noise Explosion risk Apparently harmless substances in closed containers may generate excessi...

Страница 10: ...s specified in the standard The user is responsible for any interference caused by welding In order to evaluate any possible problems with electromagnetic compatibility in the surrounding area the use...

Страница 11: ...placement parts etc from our range of products Only insert and lock accessory components into the relevant connection socket when the ma chine is switched off Requirements for connection to the public...

Страница 12: ...on or connection points can heat up significantly during operation water cooled version When opening the coolant circuit escaping coolant may cause scalding Open the coolant circuit only when the powe...

Страница 13: ...e dures indicated at the rating plate Hazards may arise for persons animals and material objects if the equipment is not used correctly No liability is accepted for any damages arising from improper u...

Страница 14: ...2 3 Welding in environments with increased electrical hazards Power sources with this marking can be used for welding in an environment with increased electrical hazard e g boilers For this purpose ap...

Страница 15: ...ion 0 1 Carrying strap see 5 1 4 1 chapter 2 Machine control see 4 3 chapter 3 Protective cap 4 Connection socket welding current MMA Electrode holder or workpiece lead connection TIG Connection for w...

Страница 16: ...n quick overview Rear view 16 099 002128 EW501 26 01 2022 4 2 Rear view Figure 4 2 Item Symbol Description 0 1 Main Switch Switching the machine on or off 2 Cooling air inlet 3 Mains connection cable...

Страница 17: ...as cooled down welding can continue without any further measures 2 Collective interference signal light For error messages see 7 chapter 3 VRD Voltage reduction device VRD signal light see 5 4 chapter...

Страница 18: ...d cause injuries The handles straps or brackets are suitable for transport by hand only The machine must not be suspended or lifted using a crane 5 1 1 Machine cooling Insufficient ventilation results...

Страница 19: ...gases or substances can damage the machine observe maintenance intervals see 6 2 chapter Avoid large amounts of smoke steam oily fumes grinding dust and corrosive ambient air In operation Temperature...

Страница 20: ...ation of welding current leads Use an individual welding lead to the workpiece for each welding machine Figure 5 2 Fully unroll welding current leads torch hose packages and intermediate hose packages...

Страница 21: ...heck that all welding current connections are firmly secured and electrical connections are in perfect condition Set up attach or suspend all conductive power source components such as casing trans po...

Страница 22: ...operate machine using a socket that has correctly fitted protective earth Mains plug socket and lead must be checked by a qualified electrician on a regular basis When operating the generator always e...

Страница 23: ...ctrode or to move welded work pieces Figure 5 6 Item Symbol Description 0 1 Workpiece 2 Connection socket for welding current Electrode holder or workpiece lead connection 3 Electrode holder 4 Connect...

Страница 24: ...Hot start time C Main current I Current t Time Figure 5 8 5 2 4 Arcforce During the welding process arcforce prevents the electrode sticking in the weld pool with increases in current This makes it ea...

Страница 25: ...ion socket and lock by turning to the right Screw the shielding gas hose of the welding torch to the pressure regulator outlet 5 3 2 Shielding gas supply shielding gas cylinder for welding machine WAR...

Страница 26: ...selection Figure 5 12 5 3 3 1 Gas test setting the shielding gas volume If the rotary gas valve is open the shielding gas flows permanently from the welding torch no adjustment with a separate gas va...

Страница 27: ...off and bring into normal position Complete the welding task Remove the torch from the workpiece so that the arc extinguishes 5 4 Voltage reducing device Only machine variants with the VRD SVRD AUS RU...

Страница 28: ...ce matters always consult the dealer who supplied the machine Return deliveries of defective equipment subject to warranty may only be made through your dealer When replacing parts use only original s...

Страница 29: ...rollers on a regular basis depending on the degree of soiling 6 2 2 Monthly maintenance tasks Visual inspection Casing damage front rear and side walls Wheels and their securing elements Transport ele...

Страница 30: ...tem separate from unsorted municipal waste The public waste management utilities communities have created collection points at which used equipment from private households can be disposed of free of...

Страница 31: ...perating status The supply voltage is present and the machine is switched on Flashes Mains overvoltage The supply voltage is too high e g during generator operation Check the mains supply voltage and...

Страница 32: ...enerator rating Rec 9 9 kVA Cos efficiency 0 99 83 Protection class Overvoltage category Contamination level 3 Insulation class protection classification H IP 23 Residual current circuit breaker Type...

Страница 33: ...4 511621 00100 TIG 26 GDV 8m TIG welding torch rotary gas valve gas cooled de central 094 511621 00108 DM 842 Ar CO2 230bar 30l D Pressure regulator with manometer 394 002910 00030 GH 2X1 4 2M Gas hos...

Страница 34: ...o avoid injury and equipment damage the unit must only be repaired or modified by specialist skilled persons The warranty becomes null and void in the event of unauthorised interference Appoint only s...

Страница 35: ...15 094 022172 00002 Spacer KA57 3X33 5X17 5 16 092 003293 00000 Choke WD D 4 N 15 17 094 021509 00000 Casing lower section KBG 18 094 014311 00000 Sheet metal nut M5 21X15X6 19 094 021508 00000 Insul...

Страница 36: ...Service documents Circuit diagram 36 099 002128 EW501 26 01 2022 10 2 Circuit diagram Figure 10 2...

Страница 37: ...ndix Searching for a dealer 099 002128 EW501 26 01 2022 37 11 Appendix 11 1 Searching for a dealer Sales service partners www ewm group com en specialist dealers More than 400 EWM sales partners world...

Отзывы: