Rectifying faults
Error messages
099-005504-EW501
20.11.2015
95
Error
Category
Possible cause
Remedy
a)
b) c)
Error 18
(WF. Sl.)
-
x
x
No speedometer signal from
second wire feeder (slave
drive)
Check the connection and particularly the
speedometer of the second wire feeder
(slave drive).
Error 56
(no Pha)
-
-
x
Mains phase failure
Check mains voltages
Legend for categories (error reset)
a) The error message will disappear once the error has been rectified.
b) The error message can be reset by pressing a key button:
Welding machine control
Key button
RC1 / RC2
Expert
CarExpert / Progress (M3.11)
alpha Q / Concept / Basic / Basic S / Synergic /
Synergic S / Progress (M3.71) / Picomig 305
not possible
c) The error message can only be reset by switching the machine off and on again.
The shielding gas error (Err 6) can be reset by pressing the "Welding parameters" key button.
Содержание Phoenix 401 Progress puls LP MM FKW
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005504 EW501 20 11 2015...
Страница 20: ...Machine description quick overview Rear view 20 099 005504 EW501 20 11 2015 4 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Inside view 22 099 005504 EW501 20 11 2015 4 3 Inside view Figure 4 3...
Страница 105: ...Appendix A JOB List 099 005504 EW501 20 11 2015 105 11 Appendix A 11 1 JOB List Figure 11 1...
Страница 106: ...Appendix B Overview of EWM branches 106 099 005504 EW501 20 11 2015 12 Appendix B 12 1 Overview of EWM branches...