Design and function
MIG/MAG welding
099-005504-EW501
20.11.2015
61
5.10.11.1 Selecting parameters (program A)
Changes to the welding parameters can only be made when the key switch is in position "1".
Operating
element
Action
Result
Display
n x
Change welding data display over to program
display.
(LED
Prog
is on)
Select program number.
Display example: Program "1".
Set wire speed.
(Absolute value)
Set arc length correction.
Display example: "-0.8 V" correction
(Setting range: -9.9 V to +9.9 V)
1 x
Select "Dynamic" program sequence parameter.
Set dynamic. (Setting range 40 to -40)
40:
Arc hard and narrow.
-40:
Arc soft and wide.
5.10.12 MIG/MAG automatic cut-out
The welding machine ends the ignition process or the welding process with an
• ignition fault (no welding current flows within 5 s after the start signal)
• arc interruption (arc is intrerrupted for longer than 5 s)