Commissioning
Connecting the intermediate tube package to the power source
10
Item No.:099-OW0008-EWM01
5.2.2
OW ASM 2. DV PHOENIX PROGRESS D
5.2.2.1
Setting up the wire feed units
NOTE
Included in the version for decompact units!
(OW ASM 2.DV PHOENIX PROGRESS D)
A B
Figure 5-2
Item Symbol Description
0
1
Internal unit feet
2
Recesses for unit feet
3
Support
for two wire feed units
4
External casing frame
5
Press arbor bracket
CAUTION
Risk of falling!
If the wire feeds are not set up correctly on the support, they may fall, become damaged
and as a consequence cause injury to persons.
•
Always position internal wire feed feet in the relevant recesses!
•
External casing frame of the wire feeds must be positioned level on the support! (see figure,
part "B")
•
Check that the wire feeds are properly secured before any transport and every start-up
operation!
•
Observe the safety instructions on transport and setup, as well as on lifting by crane, in the
operating instructions for the power source, or for the wire feed!
•
Do not exert any tractive force on the torch tube package! If there is any possibility that
tractive forces may be unavoidable, the wire feeds must be removed from their support!
•
The press arbor bracket must not be used (even with a single wire feed)!